Print Report | Back to Test Summary

Testing Report for 2018-07-18-19-2

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 044G0564
EFIS: 0417000154
Project ID: 212618
QA Service Level: 1
DIST-CO-RTE-PM: 04-ALA-680-M2.4/M12.4
Work Description: ROADWAY REHAB, BRIDGE REPLACEMENT, RET. WALLS, TOLL SYSTEMS
Location Description: FREMONT AND AT SUNOL FROM MISSION BOULEVARD SEPARATION TO KOOPMAN ROAD UNDERCROSSING
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Yannaing Tun
Structure Rep.: Jordan Jarosz

Sample Information

DIME Sample ID: 2018-07-18-19
TL Number from the TL Form:
Sample Submitted By Organization: CT QASI - Bay Area Field Laboratory
Sample Organization Contact: (707) 649-5453
Type of Sample: Acceptance
Type of Material: SMTL TM5 - Threaded Bar
Sample Taken Date: 7/18/2018
Date that the sample was received by the laboratory/organization performing the testing: 7/20/2018
The quantity of what the sample constitutes: 4 coating dates
A brief description of the sample: A934 Purple Epoxy Coated Rebar
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Williams Form Eng

Material Information

Production or Authorization Testing: Retest
Threaded Bar Specification: ASTM A615
Threaded Bar Grade: 75
Threaded Bar Type: Deformed
Rebar Size: 9
Nut Specification for Threaded Bar: Not applicable
System Manufacturer: Williams Form Engineering
Epoxy Coating Color: Purple
Threaded Bar Application: Soil Nail
Coating Standards: ASTM A934 epoxy
Bar Heat Number(s): 100792512, 100891184
Nut Heat Number(s): Not applicable
Bar Lot Number: See emailed document
Nut Lot Number: Not applicable
Coupler Heat Number(s): Not applicable
Coupler Grade: Not applicable

Test Information

DIME Test ID: 2018-07-18-19-2
Test Method: ASTM A934-13: Standard Specification for Epoxy-Coated Prefabricated Steel Reinforcing Bars (Epoxy-Coating)
Date Tested: 7/25/2018
Verified Date: 7/26/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Lower spec. limit LSL: 10
Upper spec. limit USL: 15
Bar # for First Bar: 100891184-A2
Bar # for Second Bar: 100891184-B2
First Bar Mean: 11.79
Second Bar Mean: 12.54
Total mean value: 12.16