Print Report | Back to Test Summary

Testing Report for 2018-06-04-28-6

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 030F2504
EFIS: 0300000075
Project ID: 213406
QA Service Level: 1
DIST-CO-RTE-PM: 03-YOL,SAC-80-R11.1/R11.7,M0.0/M0.5
Work Description: SAC RIVER BOH (BRYTE BEND)
Location Description: SACRAMENTO AND YOLO COUNTIES IN WEST SACRAMENTO AND SACRAMENTO FROM 0.1 MILE WEST OF REED AVENUE UNDERCROSSING TO 0.1 MILE EAST OF SACRAMENTO RIVER BRIDGE AND OVERHEAD
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Ephrem Teweldeberhan
Structure Rep.: Brent Bullard

Sample Information

DIME Sample ID: 2018-06-04-28
TL Number from the TL Form: C704036
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (916) 227-7253
Type of Sample: Verification
Type of Material: SMTL TM6 - Steel Check Sample Plate
Sample Taken Date: 6/4/2018
Date that the sample was received by the laboratory/organization performing the testing: 6/6/2018
The quantity of what the sample constitutes: 6
A brief description of the sample: Plate samples cut from bridge.
From where was the sample collected: Source
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Bryte Bend Bridge

Material Information

Heat Number(s): A, B, C, D, E, F
Material Specification: A36
Grade: A36, A441
Thickness: .375 in .312 in
Shape: Round
Metal Foundry Manufacturer (Mill): Unknown
Plate Dimension: 3.625 in Round

Test Information

DIME Test ID: 2018-06-04-28-6
Test Method: ASTM E23-12c: Standard Test Methods for Notched Bar Impact Testing of Metallic Materials (Charpy Impact)
Date Tested: 6/14/2018
Verified Date: 6/19/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test: Test sample F
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Temperature Required: 70 oF
Minimum Energy Required: 7 ftlb
Test Temperature 1: 69 oF
Impact Energy 1: 61 ftlb
Impact Energy 2: 58 ftlb
Impact Energy 3: 60 ftlb
Average Impact Energy: 60 ftlb
Striker Radius: 8
Value Exceeds The Machine Capacity?: No