Project Information

Project ID: 213406 DEA: 030F2504 EFIS: 0300000075 QA Service Level: 1
DIST-CO-RTE-PM: 03-YOL,SAC-80-R11.1/R11.7,M0.0/M0.5
Work Description: SAC RIVER BOH (BRYTE BEND)
Location Description: SACRAMENTO AND YOLO COUNTIES IN WEST SACRAMENTO AND SACRAMENTO FROM 0.1 MILE WEST OF REED AVENUE UNDERCROSSING TO 0.1 MILE EAST OF SACRAMENTO RIVER BRIDGE AND OVERHEAD
Contractor Name: AMERICAN CIVIL CONSTRUCTORS WEST COAST LLC
Contractor Address: 3701 Mallard Drive, Benicia, CA 94510
Resident Engineer: Ephrem Teweldeberhan Structure Rep.: Brent Bullard

Sample Information

DIME Sample ID: 2018-06-04-28
TL Number from the TL Form: C704036
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Verification
Type of Material: SMTL TM6 - Steel Check Sample Plate
Sample Taken Date: 06/04/2018
Date that the sample was received by the laboratory/organization performing the testing: 06/06/2018
The quantity of what the sample constitutes: 6
A brief description of the sample: Plate samples cut from bridge.
From where was the sample collected: Source
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Bryte Bend Bridge

Material Information

Heat Number(s): A, B, C, D, E, F
Material Specification: A36
Grade: A36, A441
Thickness: .375 in .312 in
Shape: Round
Metal Foundry Manufacturer (Mill): Unknown
Plate Dimension: 3.625 in Round

Test Results

Test 1 of 6

DIME Test ID: 2018-06-04-28-1
Test Method: ASTM E23-12c: Standard Test Methods for Notched Bar Impact Testing of Metallic Materials (Charpy Impact)
Verified Date: 06/19/2018
Date Tested: 06/14/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Test sample A
Test Result Compliance:
Additional Comments When Verified:
Temperature Required 15 oF
Minimum Energy Required 7 ftlb
Test Temperature 1 14.7 oF
Impact Energy 1 9 ftlb
Impact Energy 2 10 ftlb
Impact Energy 3 7 ftlb
Average Impact Energy 9 ftlb
Striker Radius 8 mm
Value Exceeds The Machine Capacity? No

Test 2 of 6

DIME Test ID: 2018-06-04-28-2
Test Method: ASTM E23-12c: Standard Test Methods for Notched Bar Impact Testing of Metallic Materials (Charpy Impact)
Verified Date: 06/19/2018
Date Tested: 06/14/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Test sample D
Test Result Compliance:
Additional Comments When Verified:
Temperature Required 15 oF
Minimum Energy Required 7 ftlb
Test Temperature 1 14.7 oF
Impact Energy 1 47 ftlb
Impact Energy 2 45 ftlb
Impact Energy 3 31 ftlb
Average Impact Energy 41 ftlb
Striker Radius 8
Value Exceeds The Machine Capacity? No

Test 3 of 6

DIME Test ID: 2018-06-04-28-3
Test Method: ASTM E23-12c: Standard Test Methods for Notched Bar Impact Testing of Metallic Materials (Charpy Impact)
Verified Date: 06/19/2018
Date Tested: 06/14/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Test sample B
Test Result Compliance:
Additional Comments When Verified:
Temperature Required 45 oF
Minimum Energy Required 7 ftlb
Test Temperature 1 44.7 oF
Impact Energy 1 32 ftlb
Impact Energy 2 25 ftlb
Impact Energy 3 31 ftlb
Average Impact Energy 29 ftlb
Striker Radius 8
Value Exceeds The Machine Capacity? No

Test 4 of 6

DIME Test ID: 2018-06-04-28-4
Test Method: ASTM E23-12c: Standard Test Methods for Notched Bar Impact Testing of Metallic Materials (Charpy Impact)
Verified Date: 06/19/2018
Date Tested: 06/14/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Test sample E
Test Result Compliance:
Additional Comments When Verified:
Temperature Required 45 oF
Minimum Energy Required 7 ftlb
Test Temperature 1 44.7 oF
Impact Energy 1 50 ftlb
Impact Energy 2 51 ftlb
Impact Energy 3 51 ftlb
Average Impact Energy 51 ftlb
Striker Radius 8
Value Exceeds The Machine Capacity? No

Test 5 of 6

DIME Test ID: 2018-06-04-28-5
Test Method: ASTM E23-12c: Standard Test Methods for Notched Bar Impact Testing of Metallic Materials (Charpy Impact)
Verified Date: 06/19/2018
Date Tested: 06/14/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Test sample C
Test Result Compliance:
Additional Comments When Verified:
Temperature Required 70 oF
Minimum Energy Required 7 ftlb
Test Temperature 1 69 oF
Impact Energy 1 43 ftlb
Impact Energy 2 52 ftlb
Impact Energy 3 53 ftlb
Average Impact Energy 49 ftlb
Striker Radius 8
Value Exceeds The Machine Capacity? No

Test 6 of 6

DIME Test ID: 2018-06-04-28-6
Test Method: ASTM E23-12c: Standard Test Methods for Notched Bar Impact Testing of Metallic Materials (Charpy Impact)
Verified Date: 06/19/2018
Date Tested: 06/14/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Test sample F
Test Result Compliance:
Additional Comments When Verified:
Temperature Required 70 oF
Minimum Energy Required 7 ftlb
Test Temperature 1 69 oF
Impact Energy 1 61 ftlb
Impact Energy 2 58 ftlb
Impact Energy 3 60 ftlb
Average Impact Energy 60 ftlb
Striker Radius 8
Value Exceeds The Machine Capacity? No