Print Report | Back to Sample Detail

Sample Record for 2018-05-01-2

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 211778 DEA: 04235654 EFIS: 0400000680 QA Service Level: 1
DIST-CO-RTE-PM: 04-SM-101,114-1.3/2.5,5.0/5.3
Work Description: RECONSTRUCT INTERCHANGE
Location Description: SAN MATEO COUNTY AT VARIOUS LOCATIONS ON ROUTE 101 FROM 0.4 MILE NORTH OF UNIVERSITY AVENUE OVERCROSSING TO 0.6 MILE SOUTH OF HENDERSON UNDERPASS AND ON ROUTE 114 FROM WILLOW ROAD SEPARATION TO NEWBRIDGE STREET
Contractor Name: Disney/OC Jones Construction Company Inc.
Contractor Address: 533 Airport Blvd, Suite 120, Burlingame, CA 94010
Resident Engineer: Fernando Abela Structure Rep.: Oanh Bui

Sample Information

DIME Sample ID: 2018-05-01-2
TL Number from the TL Form: Unknown
Sample Submitted By Organization: CT HQ - QASI Bay Area Field Office
Sample Organization Contact: (916) 284-6784
Type of Sample: Quality Assurance
Type of Material: SMTL TM4 - Prestressing Strand
Sample Taken Date: 05/01/2018
Date that the sample was received by the laboratory/organization performing the testing: 05/07/2018
The quantity of what the sample constitutes: 6 strand packs
A brief description of the sample: .5 Prestressing Strand
From where was the sample collected: Other
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Sumiden Kie-Con Antioch

Material Information

Comments: Curve S100001R
Reel/Coil/Pack Number(s): 1 - S530809-3 2 - S530812-1 3 - S530810-3 4 - S530812-2 5 - S530811-3 6 - S530811-6
Number of Coils: 6
Group Number: Unknown
Strand Diameter: .5 in
Grade: 270
Strand Specification: ASTM A 416
Heat Number(s): S0531917
Mfg. Lot Number(s): SIPC180475
Manufacturer(s): SWPC

Test Results

Test 1 of 2

DIME Test ID: 2018-05-01-2-1
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 05/10/2018
Date Tested: 05/10/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
Heat NumberCoilArea (sqin)Peak Load (lbf)Load at EUL (lbf)Chord Modulus (Msi)Elongation (in)Tested By
S0531917S530810-30.15423763885628.11.89Fred
UTM 120KIP
Temperature 72 F
Extensometers E88766

Test 2 of 2

DIME Test ID: 2018-05-01-2-2
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 05/10/2018
Date Tested: 05/10/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
Heat NumberCoilArea (sqin)Peak Load (lbf)Load at EUL (lbf)Chord Modulus (Msi)Elongation (in)Tested By
S0531917S530811-60.15425263904527.71.84Fred
UTM 120KIP
Temperature 72 F
Extensometers E88766