Print Report | Back to Sample Detail

Sample Record for 2018-05-01-5

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 212247 DEA: 010G8004 MINOR: 01A1727 QA Service Level: 1
DIST-CO-RTE-PM: 01-MEN-1-78.0/83.5, 77.0/83.5
Work Description: Major Damage Restoration
Location Description: In Mendocino County near West port from 0.3 mile south of Wages Creek Bridge #10-137 to Solider Point Viaduct #10-271
Contractor Name: MCM Construction
Contractor Address: PO Box 620, North Highlands, Ca 95660
Resident Engineer: Grant Krueger Structure Rep.: Moussa Jandal

Sample Information

DIME Sample ID: 2018-05-01-5
TL Number from the TL Form: Unknown
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM1 - Elastomeric Bearing Pad
Sample Taken Date: 05/01/2018
Date that the sample was received by the laboratory/organization performing the testing: 05/02/2018
The quantity of what the sample constitutes: 4
A brief description of the sample: Bearing Pad
From where was the sample collected: Manufacturer
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Scougal Rubber

Material Information

Mfg. Lot Number(s): 16732-1
Material/Compound/Elastomer ID: NA
Samples Representing: 4
Description (size): 2.88" x 12" x 20"
Comments: Unknown
Description (Number of Shims): 6
Type of Bearing Pad: Steel
Description (Thickness of Shims): 14 gage
Manufacturer(s): Scougal Rubber
Batch Number: NA

Test Results

Test 1 of 4

DIME Test ID: 2018-05-01-5-1
Test Method: ASTM D2240-05re10: Standard Test Method for Rubber Property - Durometer Hardness
Verified Date: 05/10/2018
Date Tested: 05/07/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Temperature 72 f
Humidity 50 %
Reading #1 51
Reading #2 52
Reading #3 51
Reading #4 52
Reading #5 51
Mean 51.4

Test 2 of 4

DIME Test ID: 2018-05-01-5-3
Test Method: ASTM D624-00-re12: Standard Test Method for Tear Strength of Conventional Vulcanized Rubber and Thermoplastic Elastomers
Verified Date: 05/10/2018
Date Tested: 05/07/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens tested 3
UTM no data
Humidity 50 %
Temperature 70 F
Sample 1 Median Thickness 0.062 in
Sample 1 Tear Strength 222.6 lbf / in
Sample 2 Median Thickness 0.07 in
Sample 2 Tear Strength 225.7 lbf / in
Sample 3 Median Thickness 0.071 in
Sample 3 Tear Strength 208.5 lbf / in
Median of the Tear Strength Values 222.6 lb/in

Test 3 of 4

DIME Test ID: 2018-05-01-5-4
Test Method: SMTL BILST-06: (Neoprene Verification) Bilstein Test
Verified Date: 05/08/2018
Date Tested: 05/08/2018
Submitted By Organization: CT HQ - Sacramento Chemistry Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: sanchita.dey@dot.ca.gov
Organization Phone: (916) 227-7912
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Result Pass

Test 4 of 4

DIME Test ID: 2018-05-01-5-5
Test Method: ASTM D412-06a-re13: Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers-Tension
Verified Date: 05/10/2018
Date Tested: 05/09/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens tested 3
Unit of the Ultimate Tensile Values lbf per sqr in
UTM 11KIP
Humidity 50 %
Temperature 72 F
Sample 1 Median Thickness 0.064 in
Sample 1 Thickness all Within 0.003 inch? Yes
Sample 1 Ultimate Tensile 2425 lbf/in^2
Sample 1 Elongation (350% Min) Pass
Sample 2 Median Thickness 0.064 in
Sample 2 Thickness all Within 0.003 inch? Yes
Sample 2 Ultimate Tensile 2456.3 lbf/in^2
Sample 2 Elongation (350% Min) Pass
Sample 3 Median Thickness 0.063 in
Sample 3 Thickness all Within 0.003 inch? Yes
Sample 3 Ultimate Tensile 2411.4 lbf/in^2
Sample 3 Elongation (350% Min) Pass
Median of the Ultimate Tensile Values 2425 lbf/in^2