Print Report | Back to Test Summary

Testing Report for 2018-04-10-1-1

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 07290704
EFIS: 0712000076
Project ID: 210828
QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-47-0.9/2.0
Work Description: RESTORE BRIDGE SEISMIC.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Thang Ton
Structure Rep.: Noah Bruton

Sample Information

DIME Sample ID: 2018-04-10-1
TL Number from the TL Form:
Sample Submitted By Organization: CT QASI - Sacramento Field Laboratory
Sample Organization Contact: (916) 227-7263
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 4/10/2018
Date that the sample was received by the laboratory/organization performing the testing: 4/18/2018
The quantity of what the sample constitutes: 2
A brief description of the sample: A449 Anchor Rods
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: CK Johnson INdustries

Material Information

Rocap Number(s):
Heat Number(s): 6214434108
Nut Mfg. Lot Number(s): 26729
Washer Mfg. Lot Number(s): 0817-609
Bolt Specification: A449
Bolt Length(s): 20-1/4" , 18-3/4"
Nut Specification: A563
Washer Specification: F436
Finish: GALV.
Diameter/Size: 1-1/4
Bolt Mfg. Lot Number: 166399
Rocap Test Requirement(s):
Lubricant Requirements(s): Blue dye

Test Information

DIME Test ID: 2018-04-10-1-1
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Date Tested: 4/18/2018
Verified Date: 4/23/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test: A449 Stud & Nut
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Number of Samples: 1
Sample Size Area (in^2) Peak Load (lbf) Peak Load (kN) Tensile Strength (psi) Stress at Offset (psi) Load at Offset (lbf) Comments
1A A449 1.250 x 18.75\" Stud w / Nut 0.969 120745 537 124608 122315 118523 A449 Stud & Nut
UTM: 400KIP
Temperature: 72