Print Report | Back to Sample Detail

Sample Record for 2018-02-27-5

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 211076 DEA: 040K6914 QA Service Level: 1
DIST-CO-RTE-PM: 04-SF-80-8.2/8.6
Work Description: Install grease caps and repair pre-stress tendon
Location Description: In SF at the eastern span of the SF-Oakland Bay Bridge
Contractor Name: Golden State Bridge
Contractor Address: 2990 Bay Vista Court, Benicia, CA 94510
Resident Engineer: Bill Shedd Structure Rep.: Thuc Tran

Sample Information

DIME Sample ID: 2018-02-27-5
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Bay Area Field Office
Sample Organization Contact: (916) 284-6784
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 02/27/2018
Date that the sample was received by the laboratory/organization performing the testing: 02/28/2018
The quantity of what the sample constitutes: 1 lot
A brief description of the sample: A352 HH Bolt
From where was the sample collected: Distributor
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Bay Bolt

Material Information

Rocap Number(s): 1840-03
Heat Number(s): NF14101948
Nut Mfg. Lot Number(s): 387398B
Washer Mfg. Lot Number(s): 305068
Bolt Specification: A325
Bolt Length(s): 2"
Nut Specification: A563, Gr DH
Washer Specification: A436
Finish: HDG
Diameter/Size: 5/8"
Bolt Mfg. Lot Number: 362566A
Rocap Test Requirement(s): Yes
Lubricant Requirements(s): yes

Test Results

Test 1 of 8

DIME Test ID: 2018-02-27-5-2
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Verified Date: 03/02/2018
Date Tested: 03/02/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Nut Proof Load
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
SampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)CommentsTested By
5A387398B5/8\"34774154.68Nut Proof LoadBrian
UTM 400KIP
Temperature 72 F

Test 2 of 8

DIME Test ID: 2018-02-27-5-3
Test Method: ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 03/02/2018
Date Tested: 03/02/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 5A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 352566A
Finish Coating ASTM F2329 - Hot Dip
Product Markings A325 N
Size .625 in
Bolt Length 2 in
Gage Type Pass

Test 3 of 8

DIME Test ID: 2018-02-27-5-4
Test Method: ASME B1.2-83r01: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)
Verified Date: 03/02/2018
Date Tested: 03/02/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 5A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 387398B
Finish Coating ASTM F2329 - Hot Dip
Product Markings DH N
Size .625 in
Gage Type Pass

Test 4 of 8

DIME Test ID: 2018-02-27-5-5
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 03/02/2018
Date Tested: 03/02/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 5A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 352566A
Finish Coating ASTM F2329 - Hot Dip
Product Markings A325 N
Size .625 in
Bolt Length 2 in
Measurement Average 3.68 mils

Test 5 of 8

DIME Test ID: 2018-02-27-5-6
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 03/02/2018
Date Tested: 03/02/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 5A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 387398B
Finish Coating ASTM F2329 - Hot Dip
Product Markings DH N
Size .625 in
Bolt Length no data in
Measurement Average 5.71 mils

Test 6 of 8

DIME Test ID: 2018-02-27-5-7
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 03/02/2018
Date Tested: 03/02/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 5A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 305068
Finish Coating ASTM F2329 - Hot Dip
Product Markings WS
Size .625 in
Bolt Length no data in
Measurement Average 2.34 mils

Test 7 of 8

DIME Test ID: 2018-02-27-5-8
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 03/02/2018
Date Tested: 03/02/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 5A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 352566A
Finish Coating ASTM F2329 - Hot Dip
Product Markings A325 N
Size .625 in
Bolt Length 2 in
Hardness Reading Scale C Scale
Hardness Reading Average 28.75
Spacing Ok

Test 8 of 8

DIME Test ID: 2018-02-27-5-9
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 03/02/2018
Date Tested: 03/02/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 5A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 305068
Finish Coating ASTM F2329 - Hot Dip
Product Markings WS
Size .625 in
Bolt Length no data in
Hardness Reading Scale C Scale
Hardness Reading Average 33.55
Spacing Ok