Print Report | Back to Sample Detail

Sample Record for 2018-02-12-4

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 210618 DEA: 06342534 EFIS: 0600000382 COOP: 061616A2 QA Service Level: 1
DIST-CO-RTE-PM: 06-FRE-180-R74.1/R78.6
Work Description: CONSTRUCT SEGMENT 3 OF KINGS CANYON EXPRESSWAY
Location Description: FRESNO COUNTY ABOUT 8.4 MILES EAST OF FRESNO FROM 0.7 MILE WEST OF SMITH AVENUE TO 0.7 MILE EAST OF FRANKWOOD AVENUE
Contractor Name: SECURITY PAVING COMPANY, INC.
Contractor Address: 13170 TELFAIR AVENUE, SYLMAR, CA 91342
Resident Engineer: Justin Kimura Structure Rep.: Michael Trinh

Sample Information

DIME Sample ID: 2018-02-12-4
TL Number from the TL Form: Unknown
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM1 - Elastomeric Bearing Pad
Sample Taken Date: 02/12/2018
Date that the sample was received by the laboratory/organization performing the testing: 02/20/2018
The quantity of what the sample constitutes: 4
A brief description of the sample: Bearing Pad
From where was the sample collected: Manufacturer
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Seismic Energy

Material Information

Mfg. Lot Number(s): 4000401-1A1,2B1,3B1,4C1
Material/Compound/Elastomer ID: NA
Samples Representing: NA
Description (size): 2.874"x12"x15" 1.724"x12"x14"
Comments: Unknown
Description (Number of Shims): 5
Type of Bearing Pad: Steel
Description (Thickness of Shims): 14 gage
Manufacturer(s): Seismic Energy
Batch Number: NA

Test Results

Test 1 of 4

DIME Test ID: 2018-02-12-4-1
Test Method: ASTM D2240-05re10: Standard Test Method for Rubber Property - Durometer Hardness
Verified Date: 02/27/2018
Date Tested: 02/22/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Temperature 72 f
Humidity 50 %
Reading #1 53
Reading #2 53
Reading #3 53
Reading #4 53
Reading #5 53
Mean 53

Test 2 of 4

DIME Test ID: 2018-02-12-4-2
Test Method: ASTM D412-06a-re13: Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers-Tension
Verified Date: 02/27/2018
Date Tested: 02/22/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens tested 3
Unit of the Ultimate Tensile Values lbf per sqr in
UTM 2KIP
Humidity 50 %
Temperature 72 F
Sample 1 Median Thickness 0.071 in
Sample 1 Thickness all Within 0.003 inch? Yes
Sample 1 Ultimate Tensile 2865.2 lbf/in^2
Sample 1 Elongation (350% Min) Pass
Sample 2 Median Thickness 0.075 in
Sample 2 Thickness all Within 0.003 inch? Yes
Sample 2 Ultimate Tensile 2766 lbf/in^2
Sample 2 Elongation (350% Min) Pass
Sample 3 Median Thickness 0.068 in
Sample 3 Thickness all Within 0.003 inch? Yes
Sample 3 Ultimate Tensile 2823.5 lbf/in^2
Sample 3 Elongation (350% Min) Pass
Median of the Ultimate Tensile Values 2823.5 lbf/in^2

Test 3 of 4

DIME Test ID: 2018-02-12-4-3
Test Method: ASTM D624-00-re12: Standard Test Method for Tear Strength of Conventional Vulcanized Rubber and Thermoplastic Elastomers
Verified Date: 02/27/2018
Date Tested: 02/22/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens tested 3
UTM no data
Humidity 50 %
Temperature 72 F
Sample 1 Median Thickness 0.075 in
Sample 1 Tear Strength 293.3 lbf / in
Sample 2 Median Thickness 0.075 in
Sample 2 Tear Strength 293.3 lbf / in
Sample 3 Median Thickness 0.08 in
Sample 3 Tear Strength 275 lbf / in
Median of the Tear Strength Values 293.3 lb/in

Test 4 of 4

DIME Test ID: 2018-02-12-4-4
Test Method: SMTL BILST-06: (Neoprene Verification) Bilstein Test
Verified Date: 02/27/2018
Date Tested: 02/26/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Result Pass