Print Report | Back to Sample Detail

Sample Record for 2017-12-26-1

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 88888 DEA: SMTL-STOCK EFIS: SMTL-STOCK QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2017-12-26-1
TL Number from the TL Form: Unknown
Sample Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Sample Organization Contact: (916) 227-7071
Type of Sample: Quality Control
Type of Material: Cementitious
Sample Taken Date: 12/26/2017
Date that the sample was received by the laboratory/organization performing the testing: 12/26/2017
The quantity of what the sample constitutes: 9 cubes
A brief description of the sample: cement
From where was the sample collected: Other
Laboratory sample identification: CM175745
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Lehigh

Material Information

Brand: Lehigh
Mill: Redding
Type of Cementitious Material: Type II Cement

Test Results

Test 1 of 6

DIME Test ID: 2017-12-26-1-1
Test Method: ASTM C109-11: Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50mm] Cube Specimens)
Verified Date: 01/18/2019
Date Tested: 12/29/2017
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test: 3 Day Break
Test Result Compliance:
Additional Comments When Verified:
Will control cubes be used per ASTM C311? no
Compressive strength of 1st specimen (psi) 2917 psi
Compressive strength of 2nd specimen (psi) 3254 psi
Compressive strength of 3rd specimen (psi) 3027 psi
Average Compressive strength (to nearest 10 psi) 3070 psi

Test 2 of 6

DIME Test ID: 2017-12-26-1-2
Test Method: ASTM C109-11: Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50mm] Cube Specimens)
Verified Date: 01/18/2019
Date Tested: 01/02/2018
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test: 7 Day Break
Test Result Compliance:
Additional Comments When Verified:
Will control cubes be used per ASTM C311? no
Compressive strength of 1st specimen (psi) 3744 psi
Compressive strength of 2nd specimen (psi) 4204 psi
Compressive strength of 3rd specimen (psi) 3116 psi
Average Compressive strength (to nearest 10 psi) 3690 psi

Test 3 of 6

DIME Test ID: 2017-12-26-1-3
Test Method: ASTM C109-11: Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50mm] Cube Specimens)
Verified Date: 01/18/2019
Date Tested: 01/23/2018
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test: 28 Day Break
Test Result Compliance:
Additional Comments When Verified:
Will control cubes be used per ASTM C311? no
Compressive strength of 1st specimen (psi) 4551 psi
Compressive strength of 2nd specimen (psi) 4802 psi
Compressive strength of 3rd specimen (psi) 5080 psi
Average Compressive strength (to nearest 10 psi) 4810 psi

Test 4 of 6

DIME Test ID: 2017-12-26-1-4
Test Method: ASTM C204-11: Standard Test Methods for Fineness of Hydraulic Cement by Air-Permeability Apparatus
Verified Date: 01/18/2019
Date Tested: 01/12/2018
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Method Used Test Method A
Test Time 125 seconds
Fineness 4770 cm^2/g

Test 5 of 6

DIME Test ID: 2017-12-26-1-5
Test Method: ASTM C191-13: Standard Test Methods for Time of Setting of Hydraulic Cement by Vicat Needle
Verified Date: 01/18/2019
Date Tested: 12/29/2017
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Type of Water Used Type III grade reagent water
Time in minutes of last penetration greater than 25mm (E) 75 min
Time in minutes of first penetration less than 25mm (H) 90 min
Penetration reading at time E 28 mm
Penetration reading at time H 5 mm
Initial time of setting 77 min
Final time of setting 0 min
Method Used Test Method A

Test 6 of 6

DIME Test ID: 2017-12-26-1-6
Test Method: ASTM C185-15a: Standard Test Method for Air Content of Hydraulic Cement Mortar
Verified Date: 01/18/2019
Date Tested: 12/27/2017
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Specific gravity 3.15
Water Content 232
The amount of flow (In percent) 90 %
The amount of water used (In percent) 66.29 %
Net Weight of Sample 828.6 grams
Air Content 9 %