Project Information

Project ID: 210618 DEA: 06342534 EFIS: 0600000382 COOP: 061616A2 QA Service Level: 1
DIST-CO-RTE-PM: 06-FRE-180-R74.1/R78.6
Work Description: CONSTRUCT SEGMENT 3 OF KINGS CANYON EXPRESSWAY
Location Description: FRESNO COUNTY ABOUT 8.4 MILES EAST OF FRESNO FROM 0.7 MILE WEST OF SMITH AVENUE TO 0.7 MILE EAST OF FRANKWOOD AVENUE
Contractor Name: SECURITY PAVING COMPANY, INC.
Contractor Address: 13170 TELFAIR AVENUE, SYLMAR, CA 91342
Resident Engineer: Justin Kimura Structure Rep.: Michael Trinh

Sample Information

DIME Sample ID: 2018-01-09-4
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Sacramento Field Office
Sample Organization Contact: (916) 2058871
Type of Sample: Quality Assurance
Type of Material: SMTL TM4 - Prestressing Strand
Sample Taken Date: 01/09/2018
Date that the sample was received by the laboratory/organization performing the testing: 01/12/2018
The quantity of what the sample constitutes: 2 samples from each pack
A brief description of the sample: ASTM A416 seven wire uncoated steel strand
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Confab Shafter

Material Information

Comments:
Reel/Coil/Pack Number(s): 1201406140922, S800753-3
Number of Coils: 2
Group Number:
Strand Diameter: .375 in
Grade: 270
Strand Specification: ASTM A 416
Heat Number(s): 16104059, S0288188
Mfg. Lot Number(s): Same as Pack number
Manufacturer(s): Sumiden Wire Insteel

Test Results

Test 1 of 4

DIME Test ID: 2018-01-09-4-1
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 01/16/2018
Date Tested: 01/12/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
Heat NumberCoilArea (sqin)Peak Load (lbf)Load at EUL (lbf)Chord Modulus (Msi)Elongation (in)Tested By
1610405912014061409220.088233802079226.81.85Brian
UTM 120KIP
Temperature 72 F
Extensometers E88766

Test 2 of 4

DIME Test ID: 2018-01-09-4-2
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 01/16/2018
Date Tested: 01/12/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
Heat NumberCoilArea (sqin)Peak Load (lbf)Load at EUL (lbf)Chord Modulus (Msi)Elongation (in)Tested By
1610405912014061409220.088234112084926.91.81Brian
UTM 120KIP
Temperature 72 F
Extensometers E88766

Test 3 of 4

DIME Test ID: 2018-01-09-4-3
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 01/16/2018
Date Tested: 01/12/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
Heat NumberCoilArea (sqin)Peak Load (lbf)Load at EUL (lbf)Chord Modulus (Msi)Elongation (in)Tested By
S0288188S800753-30.085235812253129.11.78Brian
UTM 120KIP
Temperature 72 F
Extensometers E88766

Test 4 of 4

DIME Test ID: 2018-01-09-4-4
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 01/16/2018
Date Tested: 01/12/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
Heat NumberCoilArea (sqin)Peak Load (lbf)Load at EUL (lbf)Chord Modulus (Msi)Elongation (in)Tested By
S0288188S800753-30.085234992239829.11.9Brian
UTM 120KIP
Temperature 72 F
Extensometers E88766