Print Report | Back to Test Summary

Testing Report for 2017-12-21-3-1

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 060N9904
EFIS: 0612000114
Project ID: 211504
QA Service Level: 1
DIST-CO-RTE-PM: 06-FRE,MAD-41U-33.1/33.4,0.0/0.3
Work Description: BRIDGE SCOUR MITIGATION, SEISMIC RETROFIT AND UPGRADE RAIL.
Location Description: FRESNO AND MADERA COUNTIES NEAR FRESNO FROM 0.1 MILE NORTH OF PERRIN ROAD UNDERCROSSING TO 0.1 MILE SOUTH OF AVENUE 9 UNDERCROSSING
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Mark Mengoni
Structure Rep.: ML Bloom

Sample Information

DIME Sample ID: 2017-12-21-3
TL Number from the TL Form: Unknown
Sample Submitted By Organization: CT QASI - Sacramento Field Laboratory
Sample Organization Contact: (916) 227-7263
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 12/21/2017
Date that the sample was received by the laboratory/organization performing the testing: 12/21/2017
The quantity of what the sample constitutes: 12 of 1052
A brief description of the sample: 5/8 x 12 A449 HDG all thread
From where was the sample collected: Fabricator
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: UIS

Material Information

Rocap Number(s):
Heat Number(s): DL1610509502
Nut Mfg. Lot Number(s): N/A
Washer Mfg. Lot Number(s): N/A
Bolt Specification: A449
Bolt Length(s): 12"
Nut Specification: N/A
Washer Specification: N/A
Finish: HDG
Diameter/Size: 5/8
Bolt Mfg. Lot Number: 29947
Rocap Test Requirement(s): No
Lubricant Requirements(s): No

Test Information

DIME Test ID: 2017-12-21-3-1
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Date Tested: 1/3/2018
Verified Date: 1/4/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test: A449 All Thread Bolt
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Number of Samples: 1
Sample Size Area (in^2) Peak Load (lbf) Peak Load (kN) Tensile Strength (psi) Stress at Offset (psi) Load at Offset (lbf) Comments
1A A449 All Thread Rod 0.226 30100 133 133186 121542 27468 A449 All Thread Bolt
UTM: 400KIP
Temperature: 72