Print Report | Back to Test Summary

Testing Report for 2017-12-20-11-2

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: STOCK
EFIS: STOCK
Project ID: 88888
QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown
Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2017-12-20-11
TL Number from the TL Form: NA
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (916) 227-7253
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 12/20/2017
Date that the sample was received by the laboratory/organization performing the testing: 12/26/2017
The quantity of what the sample constitutes: 5
A brief description of the sample: A325 HDG Bolt
From where was the sample collected: Distributor
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Portland Bolt

Material Information

Rocap Number(s):
Heat Number(s): 3065481
Nut Mfg. Lot Number(s): 23855-6214130704
Washer Mfg. Lot Number(s): 0717-584
Bolt Specification: A325 / F3125
Bolt Length(s): 31-3/8"
Nut Specification: A563
Washer Specification: F436
Finish: HDG
Diameter/Size: .875
Bolt Mfg. Lot Number:
Rocap Test Requirement(s):
Lubricant Requirements(s):

Test Information

DIME Test ID: 2017-12-20-11-2
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Date Tested: 12/28/2017
Verified Date: 12/28/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test: A325 Bolt
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Number of Samples: 1
Sample Size Area (in^2) Peak Load (lbf) Peak Load (kN) Tensile Strength (psi) Stress at Offset (psi) Load at Offset (lbf) Comments
1B 7/8\" 0.462 61486 273 133087 124000 57288 A325 Bolt
UTM: 400KIP
Temperature: 72