Print Report | Back to Test Summary

Testing Report for 2017-12-14-1-7

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 08368514
EFIS: 0813000077
Project ID: 211889
QA Service Level: 1
DIST-CO-RTE-PM: 08-SBD-15-81.1/87.5&177.3/181.1
Work Description: CONSTRUCT AIF AND DEMOLISH EXISTING AIF IN YERMO
Location Description: SAN BERNARDINO COUNTY FROM 0.6 MILE NORTH OF YERMO ROAD OVERCROSSING TO 1.0 MILE SOUTH OF MINNEOLA ROAD OVERCROSSING AND FROM 1.2 MILE NORTH OF NIPTON ROAD OVERCROSSING TO 0.5 MILE SOUTH OF YATES WELL ROAD OVERCROSSING
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Darcy Davis
Structure Rep.: Luis Negrete

Sample Information

DIME Sample ID: 2017-12-14-1
TL Number from the TL Form: Unknown
Sample Submitted By Organization: CT - Unassigned/General Field Laboratory
Sample Organization Contact: (510) 385-8178
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 12/14/2017
Date that the sample was received by the laboratory/organization performing the testing: 12/14/2017
The quantity of what the sample constitutes: 8
A brief description of the sample: A325 Bolt Assemblies
From where was the sample collected: Source
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: K and J Steel

Material Information

Rocap Number(s):
Heat Number(s): 100884905, 10088218, NF14102181, 100785838, 10391980, 10498480, 10433230, 10286370
Nut Mfg. Lot Number(s): 20932-M58090, 26503-75065969, 24083-75063411, 17154-62130915, 391703A, 382494B, 344208B, 387411A
Washer Mfg. Lot Number(s): 031357, 028700, 030986, 031793, C9744, D3960 , D3161, 7250M,
Bolt Specification: F3125 / F1852
Bolt Length(s): 1-3/4", 2", 2-1/4", 2-1/2"
Nut Specification: A563 DH
Washer Specification: F436
Finish: Mechanically Galvanized
Diameter/Size: 5/8, 3/4
Bolt Mfg. Lot Number: 21576-10391980, 29403-10498480, 25113-1043323
Rocap Test Requirement(s):
Lubricant Requirements(s):

Test Information

DIME Test ID: 2017-12-14-1-7
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Date Tested: 12/22/2017
Verified Date: 1/4/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test: Nut Proof Load
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Number of Samples: 1
Sample Bolt Mfg. Lot Number Size (in) Peak Load (lbf) Peak Load (kN) Comments Tested By
3A 344208B ?\" 50718 225.6 Nut Proof Load Brian
UTM: 400KIP
Temperature: 72 F