Print Report | Back to Test Summary

Testing Report for 2017-12-14-37-3

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 110223U4
EFIS: 1112000102
Project ID: 208967
QA Service Level: 1
DIST-CO-RTE-PM: 11-SD-5,89-R29.1/R30.5
Work Description: REPLACE AND WIDEN BRIDGE, RECONSTRUCT RAMPS AND INTERSECTION.
Location Description: SAN DIEGO COUNTY IN SAN DIEGO FROM 0.4 MILE SOUTH OF GENESEE AVENUE OVERCROSSING TO SORRENTO VIADUCT
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Dave Pound
Structure Rep.: Anh Ma

Sample Information

DIME Sample ID: 2017-12-14-37
TL Number from the TL Form: C604716
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (916) 227-7253
Type of Sample: Quality Assurance
Type of Material: SMTL TM5 - Couplers
Sample Taken Date: 12/14/2017
Date that the sample was received by the laboratory/organization performing the testing: 12/15/2017
The quantity of what the sample constitutes: 8
A brief description of the sample: Couplers
From where was the sample collected: Fabricator
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Gerdau

Material Information

Production or Authorization Testing: Authorization Testing
Service or Ultimate: Service
Material Standard Code: ASTM A706
Material Grade: 60
Rebar Manufacturer: Gerdau
Coupler Manufacturer: BarSplice
Intermediate Assembler or Fabricator: Unknown
Rebar Size: 5, 6
Coupler Model: DBL BRL Zap Screwlok
Coating Standards: Uncoated
Shape of Rebar: Straight
Rebar Hoop Diameter: Unknown
Rebar Hoop Fabricator: Unknown
Coupler Component Heat/Lot Number(s): 6335, 5163
Rebar Heat Number(s): 6502861303, 6502921002
Rebar Size 2 :

Test Information

DIME Test ID: 2017-12-14-37-3
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Date Tested: 12/15/2017
Verified Date: 12/18/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test: Service Splice
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Number of Samples: 1
Sample Mfg. Lot Number(s) Size Area (sqin) Peak Load (lbf) Peak Stress (psi) Comments Tested By
3 1 #5/16mm 0.31 30220 97480 Service Splice Fred
UTM: 400KIP
Temperature: 72 F