Print Report | Back to Sample Detail

Sample Record for 2017-12-12-2

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 211784 DEA: 11085784 EFIS: 1100000064 QA Service Level: 1
DIST-CO-RTE-PM: 11-SD-163-4.1/4.9
Work Description: INTERCHANGE MODIFICATION AND OVERCROSSING WIDENING.
Location Description: SAN DIEGO COUNTY IN SAN DIEGO FROM 0.3 MILE SOUTH TO 0.5 MILE NORTH OF FRIARS ROAD OVERCROSSING
Contractor Name: Flatiron West Inc
Contractor Address: 1770 La Costa Meadows Dr., San Marcos, CA 92078
Resident Engineer: Dave Cortez Structure Rep.: Alex Balce

Sample Information

DIME Sample ID: 2017-12-12-2
TL Number from the TL Form: Unknown
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM1 - Elastomeric Bearing Pad
Sample Taken Date: 12/12/2017
Date that the sample was received by the laboratory/organization performing the testing: 12/12/2017
The quantity of what the sample constitutes: 1
A brief description of the sample: elastomeric bearing pad
From where was the sample collected: Manufacturer
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: DS Brown Seismic Energy

Material Information

Mfg. Lot Number(s): 4000427
Material/Compound/Elastomer ID: NA
Samples Representing: 32
Description (size): 4.6" X 22" X 22"
Comments: Unknown
Description (Number of Shims): 8
Type of Bearing Pad: Steel
Description (Thickness of Shims): 14 gage
Manufacturer(s): DS Brown
Batch Number: NA

Test Results

Test 1 of 4

DIME Test ID: 2017-12-12-2-1
Test Method: ASTM D2240-05re10: Standard Test Method for Rubber Property - Durometer Hardness
Verified Date: 12/19/2017
Date Tested: 12/13/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Temperature 72 f
Humidity 50 %
Reading #1 54
Reading #2 56
Reading #3 56
Reading #4 56
Reading #5 54
Mean 55.2

Test 2 of 4

DIME Test ID: 2017-12-12-2-2
Test Method: ASTM D412-06a-re13: Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers-Tension
Verified Date: 12/19/2017
Date Tested: 12/13/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens tested 3
Unit of the Ultimate Tensile Values lbf per sqr in
UTM 2KIP
Humidity 50 %
Temperature 72 F
Sample 1 Median Thickness 0.069 in
Sample 1 Thickness all Within 0.003 inch? Yes
Sample 1 Ultimate Tensile 2716.8 lbf/in^2
Sample 1 Elongation (350% Min) Pass
Sample 2 Median Thickness 0.067 in
Sample 2 Thickness all Within 0.003 inch? Yes
Sample 2 Ultimate Tensile 2559.5 lbf/in^2
Sample 2 Elongation (350% Min) Pass
Sample 3 Median Thickness 0.066 in
Sample 3 Thickness all Within 0.003 inch? Yes
Sample 3 Ultimate Tensile 2848.5 lbf/in^2
Sample 3 Elongation (350% Min) Pass
Median of the Ultimate Tensile Values 2716.8 lbf/in^2

Test 3 of 4

DIME Test ID: 2017-12-12-2-3
Test Method: ASTM D624-00-re12: Standard Test Method for Tear Strength of Conventional Vulcanized Rubber and Thermoplastic Elastomers
Verified Date: 12/19/2017
Date Tested: 12/13/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens tested 3
UTM no data
Humidity 50 %
Temperature 72 F
Sample 1 Median Thickness 0.07 in
Sample 1 Tear Strength 257.1 lbf / in
Sample 2 Median Thickness 0.066 in
Sample 2 Tear Strength 257.6 lbf / in
Sample 3 Median Thickness 0.064 in
Sample 3 Tear Strength 281.3 lbf / in
Median of the Tear Strength Values 257.6 lb/in

Test 4 of 4

DIME Test ID: 2017-12-12-2-4
Test Method: SMTL BILST-06: (Neoprene Verification) Bilstein Test
Verified Date: 12/19/2017
Date Tested: 12/15/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Result Pass