Print Report | Back to Test Summary

Testing Report for 2017-11-30-3-9

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: STOCK
EFIS: STOCK
Project ID: 88888
QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown
Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2017-11-30-3
TL Number from the TL Form: Unknown
Sample Submitted By Organization: CT QASI - Los Angeles Field Laboratory
Sample Organization Contact: (858) 285-5797
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 11/30/2017
Date that the sample was received by the laboratory/organization performing the testing: 12/5/2017
The quantity of what the sample constitutes: 500
A brief description of the sample: F1554 Grade 55 HDG Anchor Bolts
From where was the sample collected: Fabricator
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: UIS

Material Information

Rocap Number(s):
Heat Number(s): DL1610677601
Nut Mfg. Lot Number(s):
Washer Mfg. Lot Number(s):
Bolt Specification: A325
Bolt Length(s): 10-1/2"
Nut Specification: DH
Washer Specification: F436
Finish: HDG
Diameter/Size: 3/4"
Bolt Mfg. Lot Number: 75C1050ATSCG
Rocap Test Requirement(s):
Lubricant Requirements(s):

Test Information

DIME Test ID: 2017-11-30-3-9
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Date Tested: 12/7/2017
Verified Date: 12/8/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Sample No.: 1B
Rocap Number: no data
Heat Number(s): DL1610677601
Mfg. Lot Number: no data
Finish Coating: Plain and ASTM F2329 - Hot Dip
Product Markings: 01WX AB55
Size: .75 in
Bolt Length: 10.5 in
Measurement Average: 5.44 mils