Print Report | Back to Sample Detail

Sample Record for 2017-11-20-2

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 211931 DEA: 043G6414 EFIS: 0416000348 QA Service Level: 1
DIST-CO-RTE-PM: 04-NAP-29-37.0
Work Description: SCOUR REPLACE BRIDGE
Location Description: NAPA COUNTY IN CALISTOGA AT NAPA RIVER BRIDGE
Contractor Name: Valentine Corp.
Contractor Address: 111 Pelican Way, San Rafael, CA 94901
Resident Engineer: Danilo Patenia Structure Rep.: Nana Budu

Sample Information

DIME Sample ID: 2017-11-20-2
TL Number from the TL Form: C882752
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM1 - Elastomeric Bearing Pad
Sample Taken Date: 11/20/2017
Date that the sample was received by the laboratory/organization performing the testing: 11/20/2017
The quantity of what the sample constitutes: 1
A brief description of the sample: Bearing Pad
From where was the sample collected: Manufacturer
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Scougal Rubber

Material Information

Mfg. Lot Number(s): 15732-1
Material/Compound/Elastomer ID: NA
Samples Representing: 35
Description (size): .5" x 12" x 48"
Comments: Unknown
Description (Number of Shims): 0
Type of Bearing Pad: Plain
Description (Thickness of Shims): NA
Manufacturer(s): Scougal Rubber
Batch Number: NA

Test Results

Test 1 of 4

DIME Test ID: 2017-11-20-2-1
Test Method: ASTM D2240-05re10: Standard Test Method for Rubber Property - Durometer Hardness
Verified Date: 11/21/2017
Date Tested: 11/20/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Temperature 72 f
Humidity 50 %
Reading #1 55
Reading #2 56
Reading #3 56
Reading #4 55
Reading #5 56
Mean 55.6

Test 2 of 4

DIME Test ID: 2017-11-20-2-2
Test Method: ASTM D412-06a-re13: Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers-Tension
Verified Date: 11/21/2017
Date Tested: 11/20/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens tested 3
Unit of the Ultimate Tensile Values lbf per sqr in
UTM 2KIP
Humidity 50 %
Temperature 72 F
Sample 1 Median Thickness 0.077 in
Sample 1 Thickness all Within 0.003 inch? Yes
Sample 1 Ultimate Tensile 2538.9 lbf/in^2
Sample 1 Elongation (350% Min) Pass
Sample 2 Median Thickness 0.077 in
Sample 2 Thickness all Within 0.003 inch? Yes
Sample 2 Ultimate Tensile 2590.7 lbf/in^2
Sample 2 Elongation (350% Min) Pass
Sample 3 Median Thickness 0.076 in
Sample 3 Thickness all Within 0.003 inch? Yes
Sample 3 Ultimate Tensile 2526.3 lbf/in^2
Sample 3 Elongation (350% Min) Pass
Median of the Ultimate Tensile Values 2538.9 lbf/in^2

Test 3 of 4

DIME Test ID: 2017-11-20-2-3
Test Method: ASTM D624-00-re12: Standard Test Method for Tear Strength of Conventional Vulcanized Rubber and Thermoplastic Elastomers
Verified Date: 11/21/2017
Date Tested: 11/20/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens tested 3
UTM no data
Humidity 50 %
Temperature 72 F
Sample 1 Median Thickness 0.08 in
Sample 1 Tear Strength 262.5 lbf / in
Sample 2 Median Thickness 0.068 in
Sample 2 Tear Strength 264.7 lbf / in
Sample 3 Median Thickness 0.078 in
Sample 3 Tear Strength 269.2 lbf / in
Median of the Tear Strength Values 264.7 lb/in

Test 4 of 4

DIME Test ID: 2017-11-20-2-4
Test Method: SMTL BILST-06: (Neoprene Verification) Bilstein Test
Verified Date: 11/21/2017
Date Tested: 11/21/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Result Pass