Print Report | Back to Sample Detail

Sample Record for 2017-10-18-1

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 88888 DEA: SMTL-STOCK EFIS: SMTL-STOCK QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2017-10-18-1
TL Number from the TL Form: Unknown
Sample Submitted By Organization: CT - Unassigned/General Field Laboratory
Sample Organization Contact: 5625005861
Type of Sample: Quality Assurance
Type of Material: SMTL TM7 - Epoxy Coated Rebar
Sample Taken Date: 10/18/2017
Date that the sample was received by the laboratory/organization performing the testing: 10/23/2017
The quantity of what the sample constitutes: 2
A brief description of the sample: A934 Purple Epoxy Coated Rebar
From where was the sample collected: Source
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Fletcher Coating Harris Rebar

Material Information

Rebar Heat Number(s): SE1610425702
Rebar Epoxy Batch Number(s):
Rebar Coating Specification: ASTM A934
Rebar Size (#): 6
Rebar Coating Color: Purple
Rebar Manufacturer: Nucor
Rebar Coater: Fletcher Coating Company
Rebar Powder Manufacturer: Unknown
Release Number: Unknown
Quality Assurance Code: Unknown

Test Results

Test 1 of 2

DIME Test ID: 2017-10-18-1-1
Test Method: ASTM A775-07b-re14: Standard Specification for Epoxy-Coated Steel Reinforcing Bars (Epoxy Coating)
Verified Date: 10/25/2017
Date Tested: 10/25/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance: does not comply
Additional Comments When Verified:
First Bar Mean 11.89
Second Bar Mean 10.68
Lower spec. limit LSL 7
Upper spec. limit USL 12
Bar # for First Bar no data
Bar # for Second Bar no data
Total mean value 11.28
Total number of values less than LSL no data
Total number of values greater than USL no data

Test 2 of 2

DIME Test ID: 2017-10-18-1-2
Test Method: ASTM A884-13: Standard Specification for Epoxy-Coated Steel Wire and Welded Wire Reinforcement (Holiday)
Verified Date: 10/25/2017
Date Tested: 10/25/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Total Number of Holiday 0
Total Length 5
Holidays Per Linear Foot of Bar 0
Holiday Test Pass/Fail Pass