Print Report | Back to Sample Detail

Sample Record for 2017-10-10-1

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 88888 DEA: SMTL-STOCK EFIS: SMTL-STOCK QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2017-10-10-1
TL Number from the TL Form: Unknown
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM4 - Prestressing Strand
Sample Taken Date: 10/10/2017
Date that the sample was received by the laboratory/organization performing the testing: 10/10/2017
The quantity of what the sample constitutes: 4
A brief description of the sample: Epoxy coated strand
From where was the sample collected: Manufacturer
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Sumiden Wire

Material Information

Comments: Epoxy Coated
Reel/Coil/Pack Number(s): S334249-5
Number of Coils: 1
Group Number: 10868
Strand Diameter: .6 in
Grade: 270
Strand Specification: ASTM A 882
Heat Number(s): S0501217
Mfg. Lot Number(s): N/A
Manufacturer(s): Sumiden Wire

Test Results

Test 1 of 3

DIME Test ID: 2017-10-10-1-1
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 10/10/2017
Date Tested: 10/10/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
Heat NumberCoilArea (sqin)Peak Load (lbf)Load at EUL (lbf)Chord Modulus (Msi)Elongation (in)Tested By
S0501217S334249-50.215594515489028.11.81Brian
UTM 120KIP
Temperature 72 F
Extensometers E88766

Test 2 of 3

DIME Test ID: 2017-10-10-1-2
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 10/10/2017
Date Tested: 10/10/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
Heat NumberCoilArea (sqin)Peak Load (lbf)Load at EUL (lbf)Chord Modulus (Msi)Elongation (in)Tested By
S0501217S334249-50.215596235502528.42.05Brian
UTM 120KIP
Temperature 72 F
Extensometers E88766

Test 3 of 3

DIME Test ID: 2017-10-10-1-3
Test Method: ASTM A882-04a-re10: Standard Specification for Filled Epoxy-Coated Seven-Wire Prestressing Steel Strand (Withdrawn 2019) (Coating Adhesion)
Verified Date: 10/10/2017
Date Tested: 10/10/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Coating Adhesion Pass/Fail Pass