Sample Record for 2017-09-20-10
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 212393 DEA: 044K4704 EFIS: 0417000313
QA Service Level: 1
DIST-CO-RTE-PM: 04-ALA-13-4.4, 4.40
Work Description: This is a slide repair project on ALA-13-4.4 (Southbound RTE 13/ Westbound Rte 580 Off-Ramp). Construct Solider Pile Wall & regrade slope.
Location Description: In Alameda County, In Oakland, at Calaveras Avenue
Contractor Name: RGW
Contractor Address: 550 Greenville Rd., Livermore, CA 94550
Resident Engineer: Wondwosen Alemayehu Structure Rep.: Eric Urmeneta
Sample Information
DIME Sample ID: 2017-09-20-10
TL Number from the TL Form: C741437
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM5 - Threaded Bar
Sample Taken Date: 09/20/2017
Date that the sample was received by the laboratory/organization performing the testing: 09/25/2017
The quantity of what the sample constitutes: 2
A brief description of the sample: 10 Soil Nails with nut
From where was the sample collected: Fabricator
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Con-Tech systems
Material Information
Production or Authorization Testing: Authorization Testing
Threaded Bar Specification: ASTM A615
Threaded Bar Grade: 75
Threaded Bar Type: Deformed
Rebar Size: #10
Nut Specification for Threaded Bar: A615
System Manufacturer: Con Tech
Epoxy Coating Color: NA
Threaded Bar Application: Soil Nail
Coating Standards: Uncoated
Bar Heat Number(s): A170356, A170365
Nut Heat Number(s): 8290416
Bar Lot Number: Unknown
Nut Lot Number: 3947
Coupler Heat Number(s): Unknown
Coupler Grade: Unknown
Test Results
Test 1 of 4
DIME Test ID: 2017-09-20-10-1
Test Method: ASTM A615-15: Standard Specification for Deformed and Plain Carbon-Steel Bars for Concrete Reinforcement (Tensile)
Verified Date: 09/27/2017
Date Tested: 09/26/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: A615 Bar & Nut, Nut Strip Out Bar Did Not Break
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Sample | Size | Mfg Lot | Area (sqin) | Tensile Strength (psi) | Stress at Offset (psi) | Total Elongation (%) | Comments | Tested By | 1 | #10 Bar Heat #A170365, Nut Heat #3947 | B908317 | 1.27 | 117119 | 82567 | 11.3 | A615 Bar & Nut, Nut Strip Out Bar Did Not Break | Fred |
| |
Temperature
|
72 F
|
UTM
|
400KIP
|
Test 2 of 4
DIME Test ID: 2017-09-20-10-2
Test Method: ASTM A615-15: Standard Specification for Deformed and Plain Carbon-Steel Bars for Concrete Reinforcement (Tensile)
Verified Date: 09/27/2017
Date Tested: 09/26/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: A615 Bar & Nut
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Sample | Size | Mfg Lot | Area (sqin) | Tensile Strength (psi) | Stress at Offset (psi) | Total Elongation (%) | Comments | Tested By | 3 | #10 Bar Heat #A170356, Nut Heat #3947 | B908317 | 1.27 | 126774 | 92273 | 11.1 | A615 Bar & Nut | Fred |
| |
Temperature
|
72 F
|
UTM
|
400KIP
|
Test 3 of 4
DIME Test ID: 2017-09-20-10-3
Test Method: ASTM A615-15: Standard Specification for Deformed and Plain Carbon-Steel Bars for Concrete Reinforcement (Tensile)
Verified Date: 09/27/2017
Date Tested: 09/26/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: A615 Bar & Nut
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Sample | Size | Mfg Lot | Area (sqin) | Tensile Strength (psi) | Stress at Offset (psi) | Total Elongation (%) | Comments | Tested By | 4 | #10 Bar Heat #A170356, Nut Heat #3947 | B908317 | 1.27 | 125048 | 92192 | 0 | A615 Bar & Nut | Fred |
| |
Temperature
|
72 F
|
UTM
|
400KIP
|
Test 4 of 4
DIME Test ID: 2017-09-20-10-4
Test Method: ASTM A615-15: Standard Specification for Deformed and Plain Carbon-Steel Bars for Concrete Reinforcement (Tensile)
Verified Date: 09/27/2017
Date Tested: 09/26/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: A615 Bar & Nut, Nut Strip Out Bar Did Not Break
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Sample | Size | Mfg Lot | Area (sqin) | Tensile Strength (psi) | Stress at Offset (psi) | Total Elongation (%) | Comments | Tested By | 2 | #10 Bar Heat #A170365, Nut Heat #3947 | B908317 | 1.27 | 117077 | 85300 | 5.4 | A615 Bar & Nut, Nut Strip Out Bar Did Not Break | Fred |
| |
Temperature
|
72 F
|
UTM
|
400KIP
|