Print Report | Back to Test Summary

Testing Report for 2017-09-06-1-5

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: STOCK
EFIS: STOCK
Project ID: 88888
QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown
Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2017-09-06-1
TL Number from the TL Form: Unknown
Sample Submitted By Organization: CT QASI - Sacramento Field Laboratory
Sample Organization Contact: (916) 227-7263
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 9/6/2017
Date that the sample was received by the laboratory/organization performing the testing: 9/6/2017
The quantity of what the sample constitutes: 27 pieces
A brief description of the sample: nuts and all thread
From where was the sample collected: Fabricator
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Universal Industrial Sales

Material Information

Rocap Number(s):
Heat Number(s): DL16105095, DL14102883
Nut Mfg. Lot Number(s): Unytite, Dyson
Washer Mfg. Lot Number(s):
Bolt Specification: A449
Bolt Length(s): 12
Nut Specification: A563-DH
Washer Specification: N/A
Finish: hdg, hdg
Diameter/Size: 5/8
Bolt Mfg. Lot Number: 30143-B, 30143
Rocap Test Requirement(s): NR
Lubricant Requirements(s): Dyson only

Test Information

DIME Test ID: 2017-09-06-1-5
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Date Tested: 9/12/2017
Verified Date: 9/14/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test: A449 Threaded Rod
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Number of Samples: 1
Sample Size Area (in^2) Peak Load (lbf) Peak Load (kN) Tensile Strength (psi) Stress at Offset (psi) Load at Offset (lbf) Comments
3B A449 Threaded Rod 0.226 29672 131 131292 120433 27218 A449 Threaded Rod
UTM: 400KIP
Temperature: 72