Print Report | Back to Test Summary

Testing Report for 2017-08-18-2-3

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 081C5104
EFIS: 0812000324
Project ID: 211988
QA Service Level: 1
DIST-CO-RTE-PM: 08-RIV-74-17.4/17.8
Work Description: CONSTRUCT VEHICLE RINSE FACILITY
Location Description: RIVERSIDE COUNTY IN AND NEAR LAKE ELSINORE AT THE ELSINORE MAINTENANCE STATION AND FROM DEXTER AVENUE TO CONRAD AVENUE
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Nick Truong
Structure Rep.: Hien Vu

Sample Information

DIME Sample ID: 2017-08-18-2
TL Number from the TL Form: C939704
Sample Submitted By Organization: CT QASI - Los Angeles Field Laboratory
Sample Organization Contact: (858) 285-5797
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 8/18/2017
Date that the sample was received by the laboratory/organization performing the testing: 8/29/2017
The quantity of what the sample constitutes: 220
A brief description of the sample: 3/4 x 1-3/4 A325 TC Bolt assy
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Richardson Steel

Material Information

Rocap Number(s):
Heat Number(s): 20479960 Bolt 62142530 Nut 11606800 Washer
Nut Mfg. Lot Number(s):
Washer Mfg. Lot Number(s): D2268
Bolt Specification: A325
Bolt Length(s): 1-3/4
Nut Specification: A563
Washer Specification: F436
Finish: MG
Diameter/Size: 3/4
Bolt Mfg. Lot Number:
Rocap Test Requirement(s):
Lubricant Requirements(s):

Test Information

DIME Test ID: 2017-08-18-2-3
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Date Tested: 8/30/2017
Verified Date: 9/5/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test: Nut Proof Load
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Number of Samples: 1
Sample Bolt Mfg. Lot Number Size (in) Peak Load (lbf) Peak Load (kN) Comments Tested By
1C L96-132-17 ?\" 50742 225.71 Nut Proof Load Brian
UTM: 400KIP
Temperature: 72 F