Print Report | Back to Test Summary

Testing Report for 2017-08-10-1-1

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 081C5104
EFIS: 0812000324
Project ID: 211988
QA Service Level: 1
DIST-CO-RTE-PM: 08-RIV-74-17.4/17.8
Work Description: CONSTRUCT VEHICLE RINSE FACILITY
Location Description: RIVERSIDE COUNTY IN AND NEAR LAKE ELSINORE AT THE ELSINORE MAINTENANCE STATION AND FROM DEXTER AVENUE TO CONRAD AVENUE
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Nick Truong
Structure Rep.: Hien Vu

Sample Information

DIME Sample ID: 2017-08-10-1
TL Number from the TL Form: C939702
Sample Submitted By Organization: CT QASI - Los Angeles Field Laboratory
Sample Organization Contact: (858) 285-5797
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 8/10/2017
Date that the sample was received by the laboratory/organization performing the testing: 8/29/2017
The quantity of what the sample constitutes: 40
A brief description of the sample: F1554 Grade 55 HDG Anchor Bolts
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Richardson Steel

Material Information

Rocap Number(s):
Heat Number(s): Bolt 145817 Nut 6214073502 WasherC65743
Nut Mfg. Lot Number(s): 23094-6214073502
Washer Mfg. Lot Number(s): 32537
Bolt Specification: F1554 Gr 36
Bolt Length(s): 19"
Nut Specification: A563
Washer Specification: F436
Finish: HDG
Diameter/Size: 1"
Bolt Mfg. Lot Number:
Rocap Test Requirement(s):
Lubricant Requirements(s):

Test Information

DIME Test ID: 2017-08-10-1-1
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Date Tested: 8/30/2017
Verified Date: 8/31/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test: F1554 Gr 36 Bolt
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Number of Samples: 1
Sample Size Area (in^2) Peak Load (lbf) Peak Load (kN) Tensile Strength (psi) Stress at Offset (psi) Load at Offset (lbf) Comments
1A F1554 Bolt 10 Deg Wedge 0.606 44609 198 73612 47041 28507 F1554 Gr 36 Bolt
UTM: 400KIP
Temperature: 72