Print Report | Back to Sample Detail

Sample Record for 2017-08-10-7

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 212461 DEA: 033H2904 QA Service Level: 1
DIST-CO-RTE-PM: 03-NEV,NEV/PLA-80-R2.5/69.23
Work Description: Replace damaged culvert and repair sinkhole
Location Description:
Contractor Name: GRANITE CONSTRUCTION COMPANY
Contractor Address: 1900 Glendale Avenue, Sparks, NV 89431
Resident Engineer: Randie Babbini Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2017-08-10-7
TL Number from the TL Form: C925914
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM7 - Epoxy Coated Dowels
Sample Taken Date: 08/10/2017
Date that the sample was received by the laboratory/organization performing the testing: 08/14/2017
The quantity of what the sample constitutes: 2
A brief description of the sample: epoxy coated dowel basket and epoxy coated rebar basket
From where was the sample collected: Fabricator
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Dayton Superior

Material Information

Dowel Metal Heat Number: SE17102274 rebar SE17102286
Dowel Epoxy Batch Number: NA
Dowel Coating Specification: ASTM A775
Dowel Size: 1.5 in
Dowel Coating Color: Green
Dowel Manufacturer: Nucor
Dowel Coater: Dayton Superior
Release Number: 1347114-1 1347114-2
Quality Assurance Code: Unknown
Rebar Size (#):

Test Results

Test 1 of 4

DIME Test ID: 2017-08-10-7-1
Test Method: ASTM A775-07b-re14: Standard Specification for Epoxy-Coated Steel Reinforcing Bars (Epoxy Coating)
Verified Date: 08/16/2017
Date Tested: 08/16/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
First Bar Mean 10.11 mils
Second Bar Mean 12.01 mils
Lower spec. limit LSL 7 mils
Upper spec. limit USL 16 mils
Bar # for First Bar no data
Bar # for Second Bar no data
Total mean value 11.06 mils
Total number of values less than LSL no data
Total number of values greater than USL no data

Test 2 of 4

DIME Test ID: 2017-08-10-7-2
Test Method: ASTM A775-07b-re14: Standard Specification for Epoxy-Coated Steel Reinforcing Bars (Holiday)
Verified Date: 08/16/2017
Date Tested: 08/16/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Total Number of Holiday 0
Total Length 2.6 ft
Holidays Per Linear Foot of Bar 0 holiday pe
Holiday Test Pass/Fail Pass
Bend Test Pass/Fail Pass

Test 3 of 4

DIME Test ID: 2017-08-10-7-3
Test Method: ASTM A884-14: Standard Specification for Epoxy-Coated Steel Wire and Welded Wire Reinforcement (Epoxy Coating Thickness)
Verified Date: 08/16/2017
Date Tested: 08/16/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
First Bar Mean 10.18 mils
Second Bar Mean 10.35 mils
Lower spec. limit LSL 7 mils
Upper spec. limit USL 40 mils
Total mean value 10.26 mils
Total number of values less than LSL no data
Total number of values greater than USL no data

Test 4 of 4

DIME Test ID: 2017-08-10-7-4
Test Method: ASTM A884-13: Standard Specification for Epoxy-Coated Steel Wire and Welded Wire Reinforcement (Holiday)
Verified Date: 08/16/2017
Date Tested: 08/16/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Total Number of Holiday 0
Total Length 1.6 ft
Holidays Per Linear Foot of Bar 0 holiday per ft
Holiday Test Pass/Fail Pass