Testing Report for 2017-07-28-18-1

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 043G59U4
EFIS: 0415000066
Project ID: 211538
QA Service Level: 1
DIST-CO-RTE-PM: 04-ALA-205-0.0/1.004-Ala-580-0.0/8.0,26.1/30.310-SJ-580-13.5/15.4
Work Description: HMA PAVING, REPLACE APPROACH AND PCC SLABS, PRECAST CONCRETE PAVEMENT.
Location Description: ALAMEDA AND SAN JOAQUIN COUNTIES ON ROUTE 580 FROM PATTERSON PASS ROAD OVERCROSSING TO GREENVILLE ROAD OVERHEAD AND FROM EDEN CANYON ROAD UNDERCROSSING TO STROBRIDGE AVENUE UNDERCROSSING ON ROUTE 205 FROM SAN JOAQUIN COUNTY LINE TO MIDWAY ROAD UNDERCROSSI
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Eddie Dike
Structure Rep.: John Parecadan

Sample Information

DIME Sample ID: 2017-07-28-18
TL Number from the TL Form: 044682
Sample Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Sample Organization Contact: (916) 227-7283
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 7/28/2017
Date that the sample was received by the laboratory/organization performing the testing: 8/8/2017
The quantity of what the sample constitutes: 2 concrete cylinders
A brief description of the sample: concrete cylinders
From where was the sample collected: Job Site
Laboratory sample identification: Unknown
Structure unique identifier: Unknown
Structure name: Unknown
The fabricator/manufacturer/facility name: field

Material Information

The concrete mix design number: 1409541
The truck number from where the sample was collected: Unknown
The batch plant ticket number from where the sample was collected: na
Concrete batch plant: Unknown
The fabricator/manufacturer designation for the sample: Unknown
A detailed description of where the material sample was collected: field
Where the material sample would have been placed if not sampled: Unknown
From Lot No.: Unknown
Bag Lot No.: Unknown

Test Information

DIME Test ID: 2017-07-28-18-1
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Date Tested: 8/11/2017
Verified Date: 8/29/2017
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: larry.mccrum@dot.ca.gov
Organization Phone: (916) 227-7283
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 6.01 in
Average diameter of cylinder 2: 5.99 in
Cross sectional area of cylinder 1: 28.37 in^2
Cross sectional area of cylinder 2: 28.18 in^2
Compressive strength (to nearest 10 psi): 3770 psi
Maximum load on cylinder 1: 107246 lb
Maximum load on cylinder 2: 105898 lb
Compressive strength of cylinder 1: 3780.3 psi
Type of fracture pattern of cylinder 1: 1
Compressive strength of cylinder 2: 3757.9 psi
Type of fracture pattern of cylinder 2: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: no data
Age of specimen: 14 days
Age of specimen in hours: no data