Print Report | Back to Test Summary

Testing Report for 2017-07-26-1-4

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: STOCK
EFIS: STOCK
Project ID: 88888
QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown
Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2017-07-26-1
TL Number from the TL Form: Unknown
Sample Submitted By Organization: CT QASI - Bay Area Field Laboratory
Sample Organization Contact: (707) 649-5453
Type of Sample: Verification
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 7/26/2017
Date that the sample was received by the laboratory/organization performing the testing: 7/26/2017
The quantity of what the sample constitutes: 5 pcs ea
A brief description of the sample: stock hardware for anchor bolt assemblies
From where was the sample collected: Fabricator
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: UIS

Material Information

Rocap Number(s): n/a
Heat Number(s): 155816,156042,155706,DL15106136,627586,75063411,166726,62141302
Nut Mfg. Lot Number(s): DDTB, DDTN, DDSM, 24056-75063411
Washer Mfg. Lot Number(s): D3390
Bolt Specification: A449 HDG
Bolt Length(s): 5/8"x12",7/8"x18",7/8"x17",7/8"x16",7/8"x15"
Nut Specification: A563-DH HDG,plain
Washer Specification: F436
Finish: HDG,plain
Diameter/Size: 21/2" nut's,5/8x12 bolt,5/8"washer,5/8" nut,7
Bolt Mfg. Lot Number: 29346,29870,28042-B,29391,29052
Rocap Test Requirement(s): not required
Lubricant Requirements(s): none

Test Information

DIME Test ID: 2017-07-26-1-4
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Date Tested: 8/7/2017
Verified Date: 8/9/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test: A449 Bolt
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Number of Samples: 1
Sample Size Area (in^2) Peak Load (lbf) Peak Load (kN) Tensile Strength (psi) Stress at Offset (psi) Load at Offset (lbf) Comments
8A A449 7/8\" x 17\" 0.462 64936 288 140554 135486 62594 A449 Bolt
UTM: 400KIP
Temperature: 72