Print Report | Back to Test Summary

Testing Report for 2017-07-28-15-1

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 022E8004
EFIS: 0200000603
Project ID: 210580
QA Service Level: 1
DIST-CO-RTE-PM: 02-SIS-5-R7.2
Work Description: RECONSTRUCTION OF THE DUNSMUIR COMMERCIAL VEHICLE ENFORCEMENT FACILITY
Location Description: IN SISKIYOU COUNTY NEAR DUNSMUIR ATDUNSMUIR GRADE COMMERCIAL VEHICLE ENFORCEMENT FACILITY.
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Nicole Mallory
Structure Rep.: Andrew J (Andy) Osullivan

Sample Information

DIME Sample ID: 2017-07-28-15
TL Number from the TL Form: Unknown
Sample Submitted By Organization: CT - Unassigned/General Field Laboratory
Sample Organization Contact: (510) 385-8178
Type of Sample: Acceptance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 7/28/2017
Date that the sample was received by the laboratory/organization performing the testing: 7/31/2017
The quantity of what the sample constitutes: 33
A brief description of the sample: F1554 anchor bolt
From where was the sample collected: Fabricator
Laboratory sample identification: S08-016-17
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: BSMI

Material Information

Rocap Number(s):
Heat Number(s): 376816, 144917, 16205649
Nut Mfg. Lot Number(s):
Washer Mfg. Lot Number(s):
Bolt Specification: none
Bolt Length(s): 12'', 33'', 25-1/2''
Nut Specification: none
Washer Specification: none
Finish: plain
Diameter/Size: 3/4, 1''
Bolt Mfg. Lot Number:
Rocap Test Requirement(s):
Lubricant Requirements(s):

Test Information

DIME Test ID: 2017-07-28-15-1
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Date Tested: 8/3/2017
Verified Date: 8/4/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Number of Samples: 1
Sample Heat Number Diameter (in) Area (sqin) Stress at Offset (psi) Tensile Strength (psi) Elongation in 4 x d (%) Tested By
1 144917 0.498 0.195 58181 78360 30.9 Fred
UTM: 67KIP
Temperature: 72 f