Testing Report for 2017-07-31-6-2

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 06471504
EFIS: 0600000464
Project ID: 209146
QA Service Level: 1
DIST-CO-RTE-PM: 06-TUL-99-39.6/41.3
Work Description: RECONSTRUCT INTERCHANGE WITH NEW PUMPING PLANT.
Location Description: TULARE COUNTY AT GOSHEN FROM 0.9 MILE NORTH OF ROUTE 99/198 WEST SEPARATION TO 0.2 MILE NORTH OF NORTH GOSHEN OVERHEAD
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Brent Haroldsen
Structure Rep.: Peter Moua

Sample Information

DIME Sample ID: 2017-07-31-6
TL Number from the TL Form: Unknown
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (916) 227-7253
Type of Sample: Quality Assurance
Type of Material: SMTL TM5 - Couplers
Sample Taken Date: 7/31/2017
Date that the sample was received by the laboratory/organization performing the testing: 7/31/2017
The quantity of what the sample constitutes: 4
A brief description of the sample: 5 rebar DBL BRL ZAP Screwlok
From where was the sample collected: Job Site
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: CMC BarSplice

Material Information

Production or Authorization Testing: Production Testing
Service or Ultimate: Service
Material Standard Code: ASTM A706
Material Grade: 60
Rebar Manufacturer: CMC Rebar
Coupler Manufacturer: BarSplice
Intermediate Assembler or Fabricator: Unknown
Rebar Size: 5
Coupler Model: Double Barrel Zap Screwlok
Coating Standards: Uncoated
Shape of Rebar: Straight
Rebar Hoop Diameter: Unknown
Rebar Hoop Fabricator: Unknown
Coupler Component Heat/Lot Number(s): 5027 5119
Rebar Heat Number(s): 4067216
Rebar Size 2 :

Test Information

DIME Test ID: 2017-07-31-6-2
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Date Tested: 8/1/2017
Verified Date: 8/1/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test: Service Splice
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Number of Samples: 1
Sample Mfg. Lot Number(s) Size Area (sqin) Peak Load (lbf) Peak Stress (psi) Comments Tested By
2 1 #5/16mm 0.31 28885 93180 Service Splice Fred
UTM: 75KIP
Temperature: 72 F