Print Report | Back to Test Summary

Testing Report for 2017-07-27-3-4

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 060S4804
EFIS: 0615000049
Project ID: 211496
QA Service Level: 1
DIST-CO-RTE-PM: 06-TUL-65-R9.3/14.0
Work Description: COLD PLANE, PAVE WITH RHMA-G AND MODIFY SIGNAL AND LIGHTING.
Location Description: TULARE COUNTY IN AND NEAR TERRA BELLA FROM 0.7 MILE SOUTH OF AVENUE 80 TO 0.1 MILE SOUTH OF AVENUE 112
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Javier Huerta
Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2017-07-27-3
TL Number from the TL Form: C657773
Sample Submitted By Organization: CT QASI - Los Angeles Field Laboratory
Sample Organization Contact: (858) 285-5797
Type of Sample: Quality Assurance
Type of Material: SMTL TM5 - Welded Hoops
Sample Taken Date: 7/27/2017
Date that the sample was received by the laboratory/organization performing the testing: 7/28/2017
The quantity of what the sample constitutes: 30
A brief description of the sample: Resistance Butt Welded Hoops
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: TNT Rebar Cascade

Material Information

Production or Authorization Testing: Production Testing
Service or Ultimate: Service
Rebar Heat Number(s): PL16201954
Hoop Manufacturer Lot Number(s): Lot 1
Material Standard Code: ASTM A706
Material Grade: 60
Rebar Size: 5
Diameter of Hoop: 2'-8"
Epoxy Coated: No
Epoxy Coating Color: NA
Rebar Manufacturer: Nucor
Welding Company: TNT Rebar
Coating Standards: Uncoated
Weld Type: Flash Welded

Test Information

DIME Test ID: 2017-07-27-3-4
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Date Tested: 7/28/2017
Verified Date: 7/28/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test: necking okay
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Number of Samples: 1
Sample Mfg. Lot Number(s) Size Area (sqin) Peak Load (lbf) Peak Stress (psi) Comments Tested By
4 1 #5/16mm 0.31 31206 100670 necking okay Fred
UTM: 75KIP
Temperature: 72 F