Print Report | Back to Test Summary

Testing Report for 2017-07-13-2-6

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 050G0404
EFIS: 0500020020
Project ID: 211616
QA Service Level: 1
DIST-CO-RTE-PM: 05-SLO,MON-101-63.2/R69.3,R0.0/R1.9
Work Description: ROADWAY REHABILITATION AND BRIDGE CONSTRUCTION.
Location Description: SAN LUIS OBISPO AND MONTERY COUNTIES NEAR PASO ROBLES FROM 0.5 MILE SOUTH OF SAN MARCOS CREEK BRIDGE TO 0.2 MILE SOUTH OF BRADLEY ROAD OVERCROSSING
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Andrew Borrelli
Structure Rep.: Garret Hilton

Sample Information

DIME Sample ID: 2017-07-13-2
TL Number from the TL Form: Unknown
Sample Submitted By Organization: CT - Unassigned/General Field Laboratory
Sample Organization Contact: (510) 385-8178
Type of Sample: Quality Assurance
Type of Material: SMTL TM5 - Headed Bars
Sample Taken Date: 7/13/2017
Date that the sample was received by the laboratory/organization performing the testing: 7/20/2017
The quantity of what the sample constitutes: 4
A brief description of the sample: 8 HRC 120 End Anchors
From where was the sample collected: Manufacturer
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: HRC

Material Information

Production or Authorization Testing: Authorization Testing
Rebar Heat Number(s): PL17104810
Head Manufacturer Lot Number(s): B1121731
Rebar Size: #8
Headed Bar Model Name: HRC 120
Size of Head: Full Size - 9x
Head Connection Type: Friction Weld
Head Shape: Square
Rebar Manufacturer: Nucor
Head Manufacturer: Nucor
Head Fabricator: HRC
Material Standard Code: ASTM A706

Test Information

DIME Test ID: 2017-07-13-2-6
Test Method: ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Date Tested: 7/20/2017
Verified Date: 7/21/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test: Bar Broke; OK Necking
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Number of Headed Bar Samples: 1
Lot # Area (sqin) Peak Load (lbf) Tensile Strength (psi) Comments Tested By
2 0.79 72960 92350 Bar Broke Fred
Temperature: 72 F
UTM: 400KIP