Print Report | Back to Test Summary

Testing Report for 2017-07-07-12-6

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 051J1304
EFIS: 0517000064
Project ID: 212164
QA Service Level: 1
DIST-CO-RTE-PM: 05-MON-1-45.52
Work Description: Pfeiffer Canyon Emergency Bridge Replacement Project
Location Description: Highway 1 at Pfeiffer State Park
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Tyler Lavering
Structure Rep.: David Galarza

Sample Information

DIME Sample ID: 2017-07-07-12
TL Number from the TL Form: NA
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (916) 227-7253
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 7/7/2017
Date that the sample was received by the laboratory/organization performing the testing: 7/12/2017
The quantity of what the sample constitutes: 31
A brief description of the sample: fastener Assembly
From where was the sample collected: Manufacturer
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: C K Johnson

Material Information

Rocap Number(s):
Heat Number(s):
Nut Mfg. Lot Number(s): 383614C, 380140B
Washer Mfg. Lot Number(s): 0317 467, 0616-263, 302599
Bolt Specification: A325
Bolt Length(s): 2.75, 3.25, 2, 3, 1.75
Nut Specification: A563
Washer Specification: F436
Finish: HDG
Diameter/Size: .75, .5
Bolt Mfg. Lot Number: 384861A, 381375A, 777022, 388556A, 375486A
Rocap Test Requirement(s):
Lubricant Requirements(s):

Test Information

DIME Test ID: 2017-07-07-12-6
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Date Tested: 7/13/2017
Verified Date: 7/17/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test: Nut Proof Load
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Number of Samples: 1
Sample Bolt Mfg. Lot Number Size (in) Peak Load (lbf) Peak Load (kN) Comments Tested By
5A S3808817 1/2\" 21493 95.61 Nut Proof Load Fred
UTM: 400KIP
Temperature: 72 F