Project Information

DEA: 072159U4
EFIS: 0715000160
Project ID: 211260
QA Service Level: 1
DIST-CO-RTE-PM: 07-LA,ORA-5-0.0/1.5, 44.3/44.4
Work Description: CONSTRUCT HOV LANES AND MIX FLOW LANES.
Location Description: LOS ANGELES AND ORANGE COUNTIES IN BUENA PARK, LA MIRADA, CERRITOS AND SANTA FE SPRINGS FROM ARTESIA BOULEVARD UNDERCROSSING TO NORTH FORK COYOTE CREEK
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: George Saker
Structure Rep.: Danny Lalonde

Sample Information

DIME Sample ID: 2017-06-13-1
TL Number from the TL Form: C657763
Sample Submitted By Organization: CT QASI - Los Angeles Field Laboratory
Sample Organization Contact: (858) 285-5797
Type of Sample: Quality Assurance
Type of Material: SMTL TM5 - Welded Hoops
Sample Taken Date: 6/13/2017
Date that the sample was received by the laboratory/organization performing the testing: 6/19/2017
The quantity of what the sample constitutes: 170
A brief description of the sample: Resistance Butt Welded Hoops
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: RKR Steel Welding Nucor

Material Information

Production or Authorization Testing: Production Testing
Service or Ultimate: Ultimate
Rebar Heat Number(s): PL16205338
Hoop Manufacturer Lot Number(s): Lot 1 and 2
Material Standard Code: ASTM A706
Material Grade: 60
Rebar Size: 8
Diameter of Hoop: 5'-2"
Epoxy Coated: No
Epoxy Coating Color: NA
Rebar Manufacturer: Nucor
Welding Company: RKR Steel Welding
Coating Standards: Uncoated
Weld Type: Flash Welded

Test Information

DIME Test ID: 2017-06-13-1-2
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Date Tested: 6/21/2017
Verified Date: 6/21/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test: Bar Broke; OK Necking
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Number of Samples: 1
Sample Mfg. Lot Number(s) Size Area (sqin) Peak Load (lbf) Peak Stress (psi) Comments Tested By
2 1 #8/25mm 0.79 71960 91090 Bar Broke Brian
UTM: 400KIP
Temperature: 72 F