Print Report | Back to Sample Detail

Sample Record for 2017-06-06-8

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 211600 DEA: 081E0104 EFIS: 0813000117 QA Service Level: 1
DIST-CO-RTE-PM: 08-SBD-15-37.8/40.2
Work Description: CONSTRUCT CONCRETE BARRIER
Location Description: SAN BERNARDINO COUNTY IN VICTORVILLE FROM 0.2 MILE NORTH OF BEAR VALLEY OVERCROSSING TO 0.3 MILE SOUTH OF PALMDALE ROAD OVERCROSSING
Contractor Name: CHUMO CONSTRUCTION INC
Contractor Address: 14425 JOANBRIDGE STREET, BALDWIN PARK CA 91706
Resident Engineer: Thanh Pham Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2017-06-06-8
TL Number from the TL Form: 060617
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 06/06/2017
Date that the sample was received by the laboratory/organization performing the testing: 06/12/2017
The quantity of what the sample constitutes: 2
A brief description of the sample: 6X12
From where was the sample collected: Job Site
Laboratory sample identification: 959-617
Structure unique identifier: K RAIL
Structure name: STA 545 40
The fabricator/manufacturer/facility name: ROBERTSONS

Material Information

The concrete mix design number: SC590M35
The truck number from where the sample was collected: Unknown
The batch plant ticket number from where the sample was collected: NP
Concrete batch plant: Unknown
The fabricator/manufacturer designation for the sample: Unknown
A detailed description of where the material sample was collected: LOAD 2
Where the material sample would have been placed if not sampled: K RAIL
From Lot No.: Unknown
Bag Lot No.: Unknown

Test Results

Test 1 of 1

DIME Test ID: 2017-06-06-8-1
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 06/13/2017
Date Tested: 06/13/2017
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With no density determined
Capped in accordance with? ASTM C617/CTM521
Average diameter of cylinder 1 5.98 in
Average diameter of cylinder 2 6.00 in
Cross sectional area of cylinder 1 28.09 in^2
Cross sectional area of cylinder 2 28.27 in^2
Compressive strength (to nearest 10 psi) 4340 psi
Maximum load on cylinder 1 120170 lb
Maximum load on cylinder 2 124420 lb
Compressive strength of cylinder 1 4278.0 psi
Type of fracture pattern of cylinder 1 2
Compressive strength of cylinder 2 4401.1 psi
Type of fracture pattern of cylinder 2 2
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 no data
Age of specimen 7 days
Age of specimen in hours no data