Testing Report for 2017-05-15-8-1

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 080R1204
EFIS: 0812000026
Project ID: 211714
QA Service Level: 1
DIST-CO-RTE-PM: 08-SBD-40-0.0/R25.0
Work Description: REGRADE MEDIAN CROSS SLOPE
Location Description: SAN BERNARDINO COUNTY IN AND NEAR BARSTOW FROM JUNCTION 15/40 TO 1.4 MILES EAST OF FORT CADY ROAD OVERCROSSING
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Thanh Pham
Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2017-05-15-8
TL Number from the TL Form: 051517-1
Sample Submitted By Organization: CT - Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 5/15/2017
Date that the sample was received by the laboratory/organization performing the testing: 5/19/2017
The quantity of what the sample constitutes: 2
A brief description of the sample: 6X12
From where was the sample collected: Job Site
Laboratory sample identification: 957-45
Structure unique identifier: Unknown
Structure name: Unknown
The fabricator/manufacturer/facility name: HI GRADE

Material Information

The concrete mix design number: CT590F25
The truck number from where the sample was collected: Unknown
The batch plant ticket number from where the sample was collected: NP
Concrete batch plant: Unknown
The fabricator/manufacturer designation for the sample: Unknown
A detailed description of where the material sample was collected: TRUCK
Where the material sample would have been placed if not sampled: Unknown
From Lot No.: Unknown
Bag Lot No.: Unknown

Test Information

DIME Test ID: 2017-05-15-8-1
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Date Tested: 6/12/2017
Verified Date: 6/12/2017
Submitted By Organization: CT - Southern Regional Laboratory
Organization Address: 13970 Victoria St,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 213-792-4794
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 6.01 in
Average diameter of cylinder 2: 6.02 in
Cross sectional area of cylinder 1: 28.37 in^2
Cross sectional area of cylinder 2: 28.46 in^2
Compressive strength (to nearest 10 psi): 4830 psi
Maximum load on cylinder 1: 137500 lb
Maximum load on cylinder 2: 137160 lb
Compressive strength of cylinder 1: 4846.7 psi
Type of fracture pattern of cylinder 1: 1
Compressive strength of cylinder 2: 4819.4 psi
Type of fracture pattern of cylinder 2: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: no data
Age of specimen: 28 days
Age of specimen in hours: no data