Print Report | Back to Test Summary

Testing Report for 2016-12-01-9-1

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 044G4604
EFIS: 0412000480
Project ID: 210871
QA Service Level: 1
DIST-CO-RTE-PM: 04-MRN-101-1.5/14.0
Work Description: REMOVE EXISTING AND CONSTRUCT NEW BRIDGE RAILINGS.
Location Description: IN MARIN COUNTY, AT VARIOUS LOCATION, FROM SPENCER AVE OVERCROSSING TO NORTH BRANCHGALLINAS CREEK BRIDGE
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Hal Streater
Structure Rep.: Long Li

Sample Information

DIME Sample ID: 2016-12-01-9
TL Number from the TL Form: C859788
Sample Submitted By Organization: CT HQ - Sacramento Aggregate Testing Laboratory
Sample Organization Contact: (916) 227-7204
Type of Sample: Annual Source Testing
Type of Material: Aggregate
Sample Taken Date: 12/1/2016
Date that the sample was received by the laboratory/organization performing the testing: 3/14/2017
The quantity of what the sample constitutes: 1 bag
A brief description of the sample: 1/2 x 4 PCC Aggregate
From where was the sample collected: Source
Laboratory sample identification: 17CPCC-0103
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Cemex Clayton

Material Information

Source Identification (SMARA or name of Pit): 91-07-0004::CLAYTON
The fabricator's/manufacturer's product name for the sample: Unknown
The fabricator/manufacturer designation for the sample: Unknown
The plant number: Unknown
A detailed description of where the material sample was collected: Stockpile @ Plant
Where the material sample would have been placed if not sampled: Unknown
Primary Aggregate Nominal Size: 1/2 inch
The concrete mix design number: Unknown
Lot number:
Sublot number:

Test Information

DIME Test ID: 2016-12-01-9-1
Test Method: CTM 214-August 2010: Method of Test for Soundness of Aggregates by Use of Sodium Sulfate
Date Tested: 6/9/2017
Verified Date: 6/14/2017
Submitted By Organization: CT HQ - Sacramento Aggregate Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: bang.d.nguyen@dot.ca.gov
Organization Phone: (916) 227-7204
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified :

Submitted Test Results

Percentage Loss of material retained on 2 x 1 ½ in. sieve: no data
Percentage Loss of material retained on 1 ½ x 1 in. sieve: no data
Percentage Loss of material retained on 1 x ¾ in. sieve: no data
Percentage Loss of material retained on ¾ x ½ in. sieve: no data
Percentage Loss of material retained on ½ x ⅜ in. sieve: no data
Percentage Loss of material retained on ⅜ in. x #4 sieve: no data
Weighted Average Percent Loss of Coarse Aggregate: 4.6 %