Print Report | Back to Test Summary

Testing Report for 2017-05-24-7-5

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 59912684
EFIS:
Project ID: 8196
QA Service Level: 1
DIST-CO-RTE-PM: 59---
Work Description:
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown
Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2017-05-24-7
TL Number from the TL Form: Unknown
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (916) 227-7253
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 5/24/2017
Date that the sample was received by the laboratory/organization performing the testing: 6/5/2017
The quantity of what the sample constitutes: 9
A brief description of the sample: F1554 Grade 55 HDG Anchor Bolts
From where was the sample collected: Distributor
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: A M Nut and Bolt

Material Information

Rocap Number(s):
Heat Number(s): 3068594, 3066882, 3066144
Nut Mfg. Lot Number(s): 383997A, 385999A, 24298-6214105002
Washer Mfg. Lot Number(s): 2038077, 2014320, 2047508
Bolt Specification: F1554
Bolt Length(s): 36", 18", 42"
Nut Specification: A563
Washer Specification: F436
Finish: HDG
Diameter/Size: 1", 0.75", 1.5"
Bolt Mfg. Lot Number:
Rocap Test Requirement(s):
Lubricant Requirements(s):

Test Information

DIME Test ID: 2017-05-24-7-5
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Date Tested: 6/8/2017
Verified Date: 6/12/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test: Nut Proof Load
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Number of Samples: 1
Sample Bolt Mfg. Lot Number Size (in) Peak Load (lbf) Peak Load (kN) Comments Tested By
2A B30112617 3/4\" 59060 262.71 Nut Proof Load Fred
UTM: 400KIP
Temperature: 70 F