Print Report | Back to Test Summary

Testing Report for 2017-06-01-9-4

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 120F96E4
EFIS: 1200020279
Project ID: 209046
QA Service Level: 1
DIST-CO-RTE-PM: 12-ORA-5,162-6.2/8.7
Work Description: CONSTRUCT HOV LANE. RECONSTRUCT RAMPS AND STRUCTURES WIDENING,
Location Description: ORANGE COUNTY FROM 0.4 MILE NORTH OF CAMINO DE ESTRELLA OVERCROSSING TO 0.2 MILE SOUTH OF SAN JUAN CREEK ROAD UNDERCROSSING
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Irvin Nguyen
Structure Rep.: Parvin Sebti

Sample Information

DIME Sample ID: 2017-06-01-9
TL Number from the TL Form: C836753
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (916) 227-7253
Type of Sample: Quality Assurance
Type of Material: SMTL TM5 - Couplers
Sample Taken Date: 6/1/2017
Date that the sample was received by the laboratory/organization performing the testing: 6/7/2017
The quantity of what the sample constitutes: 12
A brief description of the sample: Couplers
From where was the sample collected: Job Site
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Gerdau Dayton Superior

Material Information

Production or Authorization Testing: Authorization Testing
Service or Ultimate: Service
Material Standard Code: ASTM A706
Material Grade: 60
Rebar Manufacturer: Gerdau
Coupler Manufacturer: Dayton Superior
Intermediate Assembler or Fabricator: Unknown
Rebar Size: 4, 5, 11
Coupler Model: Screwlok
Coating Standards: Uncoated
Shape of Rebar: Straight
Rebar Hoop Diameter: Unknown
Rebar Hoop Fabricator: Unknown
Coupler Component Heat/Lot Number(s): 74101369, MM16106575, 73101028
Rebar Heat Number(s): 65026106, 65026508, 65025236
Rebar Size 2 :

Test Information

DIME Test ID: 2017-06-01-9-4
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Date Tested: 6/7/2017
Verified Date: 6/7/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test: Service Splice
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Number of Samples: 1
Sample Mfg. Lot Number(s) Size Area (sqin) Slip (inch) Peak Load (lbf) Peak Stress (psi) Comments Tested By
3 #4/13mm 0.2 0 18736 93680 Service Splice Brian
Temperature: 72 F
UTM: 75KIP
Halo ID: Small