Print Report | Back to Test Summary

Testing Report for 2017-05-26-4-2

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 010B5404
EFIS: 0112000136
Project ID: 211774
QA Service Level: 1
DIST-CO-RTE-PM: 01-MEN-162-13.9,22.7
Work Description: REPAIR ROADWAY AND CONSTRUCT WALL
Location Description: MENDOCINO COUNTY NEAR DOS RIOS AT 1.2 MILES WEST OF MIDDLE FORK EEL RIVER BRIDGE AND AT 2.8 MILES EAST OF SAND BANK CREEK
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Dwayne Grandy
Structure Rep.: Chandra Bapat

Sample Information

DIME Sample ID: 2017-05-26-4
TL Number from the TL Form:
Sample Submitted By Organization: CT QASI - Sacramento Field Laboratory
Sample Organization Contact: (916) 227-7263
Type of Sample: Acceptance
Type of Material: SMTL TM1 - Elastomeric Bearing Pad
Sample Taken Date: 5/26/2017
Date that the sample was received by the laboratory/organization performing the testing: 6/5/2017
The quantity of what the sample constitutes: 24
A brief description of the sample: 1x8x10 Beraing Pad
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Scougal Rubber

Material Information

Mfg. Lot Number(s): 15637
Material/Compound/Elastomer ID: CP2527V CP2628A RS 7030
Samples Representing: 24
Description (size): 1 x 8 x 10
Comments:
Description (Number of Shims): 2
Type of Bearing Pad: Steel
Description (Thickness of Shims): 14 gage
Manufacturer(s): Scougal Rubber
Batch Number: 0

Test Information

DIME Test ID: 2017-05-26-4-2
Test Method: ASTM D412-06a-re13: Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers—Tension
Date Tested: 6/5/2017
Verified Date: 6/12/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

UTM: 2KIP
Humidity: 50 %
Temperature: 72 F
Sample 1 Median Thickness: 0.07 in
Sample 1 Thickness all Within 0.003 inch?: Yes
Sample 1 Ultimate Tensile: 2857.1 lbf/in^2
Sample 1 Elongation (350% Min): Pass
Sample 2 Median Thickness: 0.073 in
Sample 2 Thickness all Within 0.003 inch?: Yes
Sample 2 Ultimate Tensile: 2623 lbf/in^2
Sample 2 Elongation (350% Min): Pass
Sample 3 Median Thickness: 0.071 in
Sample 3 Thickness all Within 0.003 inch?: Yes
Sample 3 Ultimate Tensile: 2921.3 lbf/in^2
Sample 3 Elongation (350% Min): Pass
Median of the Ultimate Tensile Values: 2857.1 lbf/in^2