Print Report | Back to Sample Detail

Sample Record for 2017-05-05-10

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 211718 DEA: 120H5304 EFIS: 1213000147 QA Service Level: 1
DIST-CO-RTE-PM: 12-ORA-5-6.8,22.8
Work Description: BRIDGE RAIL UPGRADE AND DECK REPLACEMENT
Location Description: ORANGE COUNTY IN SAN JUAN CAPISTRANO AND IRVINE AT NORTHBOUND CAMINO LAS RAMBLAS LOOP ON RAMP AND NEAR BEE CANYON CREEK
Contractor Name: UNITED ENGINEERING & CONSTRUCTION, INC
Contractor Address: 336 N Central Ave, Glendale, CA 91203
Resident Engineer: Irvin Nguyen Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2017-05-05-10
TL Number from the TL Form: C970155
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM5 - Headed Bars
Sample Taken Date: 05/05/2017
Date that the sample was received by the laboratory/organization performing the testing: 05/15/2017
The quantity of what the sample constitutes: 4
A brief description of the sample: Barsplice Button Head End Anchor
From where was the sample collected: Fabricator
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Cascade Barsplice

Material Information

Production or Authorization Testing: Production Testing
Rebar Heat Number(s): 412716
Head Manufacturer Lot Number(s): 1
Rebar Size: #11
Headed Bar Model Name: Barsplice Buttonhead 10AB
Size of Head: Reduced Size - 4x
Head Connection Type: Crimped Head
Head Shape: Circular
Rebar Manufacturer: Cascade
Head Manufacturer: Barsplice
Head Fabricator: Barsplice
Material Standard Code: ASTM A706
Headed Bar Unique ID:

Test Results

Test 1 of 3

DIME Test ID: 2017-05-05-10-1
Test Method: ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Verified Date: 05/16/2017
Date Tested: 05/16/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Bar Broke; OK Necking
Test Result Compliance:
Additional Comments When Verified:
Number of Headed Bar Samples 1
Lot #Area (sqin)Peak Load (lbf)Tensile Strength (psi)CommentsTested By
11.5615233097650Bar BrokeFred
Temperature 72 F
UTM 400KIP

Test 2 of 3

DIME Test ID: 2017-05-05-10-2
Test Method: ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Verified Date: 05/16/2017
Date Tested: 05/16/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Bar Broke; OK Necking
Test Result Compliance:
Additional Comments When Verified:
Number of Headed Bar Samples 1
Lot #Area (sqin)Peak Load (lbf)Tensile Strength (psi)CommentsTested By
11.5615396098690Bar BrokeFred
Temperature 72 F
UTM 400KIP

Test 3 of 3

DIME Test ID: 2017-05-05-10-3
Test Method: ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Verified Date: 05/16/2017
Date Tested: 05/16/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Bar Broke; OK Necking
Test Result Compliance:
Additional Comments When Verified:
Number of Headed Bar Samples 1
Lot #Area (sqin)Peak Load (lbf)Tensile Strength (psi)CommentsTested By
11.5615248097740Bar BrokeFred
Temperature 72 F
UTM 400KIP