Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 8196 DEA: 59912684
QA Service Level: 1
DIST-CO-RTE-PM: 59---
Work Description:
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown
DIME Sample ID: 2017-04-25-3
TL Number from the TL Form: Unknown
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM4 - Prestressing Strand
Sample Taken Date: 04/25/2017
Date that the sample was received by the laboratory/organization performing the testing: 04/28/2017
The quantity of what the sample constitutes: 60
A brief description of the sample: Prestressing Strand
From where was the sample collected: Manufacturer
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Sumiden Wire
Comments: Unknown
Reel/Coil/Pack Number(s):
Number of Coils: 61
Group Number: 10859
Strand Diameter: .620 in
Grade: 270
Strand Specification: ASTM A 416
Heat Number(s): S0288722 S0288882 S0288883 S0288884 S0288885 S0288890 S0290079 S0290085-2 S0514316 S0514316-2 S0518716 S0522816 S0523016 S0523116 S0543516
Mfg. Lot Number(s): na
Manufacturer(s): Sumiden Wire
DIME Test ID: 2017-04-25-3-1
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 05/04/2017
Date Tested: 05/02/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By | S0288722 | S333984-5 | 0.021 | 59135 | 54583 | 313.3 | 1.94 | Arnold |
| |
UTM
|
120KIP
|
Temperature
|
70 F
|
Extensometers
|
E88766
|
DIME Test ID: 2017-04-25-3-2
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 05/04/2017
Date Tested: 05/03/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By | S0288722 | S333988-1 | 0.213 | 59947 | 55120 | 28.4 | 1.81 | Arnold |
| |
UTM
|
120KIP
|
Temperature
|
70 F
|
Extensometers
|
E88766
|
DIME Test ID: 2017-04-25-3-3
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 05/04/2017
Date Tested: 05/03/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By | S0288722 | S333985-1 | 0.213 | 60003 | 55350 | 28.6 | 1.83 | Arnold |
| |
UTM
|
120KIP
|
Temperature
|
70 F
|
Extensometers
|
E88766
|
DIME Test ID: 2017-04-25-3-4
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 05/04/2017
Date Tested: 05/03/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By | S0288882 | S333986-1 | 0.213 | 60083 | 55630 | 28.8 | 2.11 | Arnold |
| |
UTM
|
120KIP
|
Temperature
|
70 F
|
Extensometers
|
E88766
|
DIME Test ID: 2017-04-25-3-5
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 05/04/2017
Date Tested: 05/03/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By | S0288882 | S333988-5 | 0.213 | 60229 | 55604 | 28.3 | 1.75 | Arnold |
| |
UTM
|
120KIP
|
Temperature
|
70 F
|
Extensometers
|
E88766
|
DIME Test ID: 2017-04-25-3-6
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 05/04/2017
Date Tested: 05/03/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By | S0288883 | S333968-5 | 0.213 | 59566 | 55792 | 28.6 | 1.71 | Arnold |
| |
UTM
|
120KIP
|
Temperature
|
70 F
|
Extensometers
|
E88766
|
DIME Test ID: 2017-04-25-3-7
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 05/04/2017
Date Tested: 05/03/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By | S0288884 | S333974-1 | 0.214 | 59443 | 55506 | 28.6 | 1.81 | Arnold |
| |
UTM
|
120KIP
|
Temperature
|
70 F
|
Extensometers
|
E88766
|
DIME Test ID: 2017-04-25-3-8
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 05/04/2017
Date Tested: 05/03/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By | S0288884 | S333974-3 | 0.214 | 59819 | 55747 | 28.1 | 1.66 | Arnold |
| |
UTM
|
120KIP
|
Temperature
|
70 F
|
Extensometers
|
E88766
|
DIME Test ID: 2017-04-25-3-9
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 05/04/2017
Date Tested: 05/03/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By | S0288885 | S333963-3 | 0.213 | 59432 | 55912 | 28.7 | 1.65 | Arnold |
| |
UTM
|
120KIP
|
Temperature
|
70 F
|
Extensometers
|
E88766
|
DIME Test ID: 2017-04-25-3-10
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 05/04/2017
Date Tested: 05/03/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By | S0288885 | S333966-3 | 0.213 | 59701 | 55261 | 27.4 | 1.72 | Arnold |
| |
UTM
|
120KIP
|
Temperature
|
70 F
|
Extensometers
|
E88766
|
DIME Test ID: 2017-04-25-3-11
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 05/04/2017
Date Tested: 05/03/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By | S0288890 | S333981-2 | 0.213 | 60132 | 55276 | 28.7 | 1.78 | Arnold |
| |
UTM
|
120KIP
|
Temperature
|
70 F
|
Extensometers
|
E88766
|
DIME Test ID: 2017-04-25-3-12
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 05/04/2017
Date Tested: 05/03/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By | S0288890 | S333981-4 | 0.213 | 60414 | 55413 | 28.5 | 1.84 | Arnold |
| |
UTM
|
120KIP
|
Temperature
|
70 F
|
Extensometers
|
E88766
|
DIME Test ID: 2017-04-25-3-13
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 05/04/2017
Date Tested: 05/03/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By | S0290079 | S333989-2 | 0.213 | 60077 | 54726 | 27.1 | 1.79 | Arnold |
| |
UTM
|
120KIP
|
Temperature
|
70 F
|
Extensometers
|
E88766
|
DIME Test ID: 2017-04-25-3-14
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 05/04/2017
Date Tested: 05/03/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By | S0290079 | S333989-3 | 0.213 | 60024 | 55448 | 28.8 | 1.73 | Arnold |
| |
UTM
|
120KIP
|
Temperature
|
70 F
|
Extensometers
|
E88766
|
DIME Test ID: 2017-04-25-3-15
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 05/04/2017
Date Tested: 05/03/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By | S0290085-2 | S334024-1 | 0.214 | 59868 | 55446 | 28.1 | 1.8 | Arnold |
| |
UTM
|
120KIP
|
Temperature
|
70 F
|
Extensometers
|
E88766
|
DIME Test ID: 2017-04-25-3-16
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 05/04/2017
Date Tested: 05/03/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By | S0290085-2 | S334024-4 | 0.214 | 59513 | 55137 | 28.3 | 1.69 | Arnold |
| |
UTM
|
120KIP
|
Temperature
|
70 F
|
Extensometers
|
E88766
|
DIME Test ID: 2017-04-25-3-17
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 05/04/2017
Date Tested: 05/03/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By | S0514316 | S333949-3 | 0.213 | 59195 | 55136 | 28.4 | 1.72 | Arnold |
| |
UTM
|
120KIP
|
Temperature
|
70 F
|
Extensometers
|
E88766
|
DIME Test ID: 2017-04-25-3-18
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 05/04/2017
Date Tested: 05/03/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By | S0514316 | S333949-5 | 0.213 | 59206 | 54961 | 28.4 | 1.68 | Arnold |
| |
UTM
|
120KIP
|
Temperature
|
70 F
|
Extensometers
|
E88766
|
DIME Test ID: 2017-04-25-3-19
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 05/04/2017
Date Tested: 05/03/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By | S0514316-2 | S333947-4 | 0.213 | 59974 | 55813 | 28.5 | 1.81 | Arnold |
| |
UTM
|
120KIP
|
Temperature
|
70 F
|
Extensometers
|
E88766
|
DIME Test ID: 2017-04-25-3-20
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 05/04/2017
Date Tested: 05/03/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By | S0514316-2 | S333947-5 | 0.214 | 59858 | 56290 | 28.4 | 1.72 | Arnold |
| |
UTM
|
120KIP
|
Temperature
|
70 F
|
Extensometers
|
E88766
|
DIME Test ID: 2017-04-25-3-21
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 05/04/2017
Date Tested: 05/03/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By | S0522816 | S333944-2 | 0.215 | 59312 | 55507 | 28.6 | 1.73 | Arnold |
| |
UTM
|
120KIP
|
Temperature
|
70 F
|
Extensometers
|
E88766
|
DIME Test ID: 2017-04-25-3-22
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 05/04/2017
Date Tested: 05/03/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By | S0522816 | S333944-3 | 0.215 | 59734 | 55693 | 28.4 | 1.9 | Arnold |
| |
UTM
|
120KIP
|
Temperature
|
70 F
|
Extensometers
|
E88766
|
DIME Test ID: 2017-04-25-3-23
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 05/04/2017
Date Tested: 05/03/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By | S0523016 | S333958-3 | 0.213 | 59194 | 54845 | 28.7 | 1.8 | Arnold |
| |
UTM
|
120KIP
|
Temperature
|
70 F
|
Extensometers
|
E88766
|
DIME Test ID: 2017-04-25-3-24
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 05/04/2017
Date Tested: 05/03/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By | S0523016 | S333961-4 | 0.214 | 59766 | 55392 | 28.5 | 1.89 | Arnold |
| |
UTM
|
120KIP
|
Temperature
|
70 F
|
Extensometers
|
E88766
|
DIME Test ID: 2017-04-25-3-25
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 05/04/2017
Date Tested: 05/03/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By | S0523116 | S333938-3 | 0.213 | 59022 | 53565 | 28.3 | 2 | Arnold |
| |
UTM
|
120KIP
|
Temperature
|
70 F
|
Extensometers
|
E88766
|
DIME Test ID: 2017-04-25-3-26
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 05/04/2017
Date Tested: 05/03/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By | S0543516 | S333929-5 | 0.213 | 59599 | 54844 | 28.5 | 1.83 | Arnold |
| |
UTM
|
120KIP
|
Temperature
|
70 F
|
Extensometers
|
E88766
|