Print Report | Back to Test Summary

Testing Report for 2017-04-21-2-3

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 120M4904
EFIS: 1212000090
Project ID: 211513
QA Service Level: 1
DIST-CO-RTE-PM: 12-ORA-5-1.2/2.2
Work Description: WIDEN FWY AND BRIDGE AND CONSTRUCT RW, SOUND WALL, AND CONC BARRIERS.
Location Description: ORANGE COUNTY IN SAN CLEMENTE FROM 0.1 MILE NORTH OF AVENIDA MENDOCINO OVERCROSSING TO 0.2 MILE SOUTH OF AVENIDA PRESIDIO UNDERCROSSING
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Steve Kinaly
Structure Rep.: Imad Karam

Sample Information

DIME Sample ID: 2017-04-21-2
TL Number from the TL Form: C943834
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (916) 227-7253
Type of Sample: Quality Assurance
Type of Material: SMTL TM5 - Headed Bars
Sample Taken Date: 4/21/2017
Date that the sample was received by the laboratory/organization performing the testing: 4/24/2017
The quantity of what the sample constitutes: 4
A brief description of the sample: Headed Bars
From where was the sample collected: Job Site
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: CMC HRC

Material Information

Production or Authorization Testing: Retest
Rebar Heat Number(s): 4061558
Head Manufacturer Lot Number(s): 1
Rebar Size: 9
Headed Bar Model Name: HRC 120
Size of Head: Reduced Size - 4x
Head Connection Type: Friction Weld
Head Shape: Square
Rebar Manufacturer: CMC
Head Manufacturer: HRC
Head Fabricator: HRC
Material Standard Code: ASTM A706

Test Information

DIME Test ID: 2017-04-21-2-3
Test Method: ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Date Tested: 4/24/2017
Verified Date: 4/25/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test: Bar Broke; OK Necking
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Number of Headed Bar Samples: 1
Lot # Area (sqin) Peak Load (lbf) Tensile Strength (psi) Comments Tested By
1 1 97550 97550 Bar Broke Brian
Temperature: 71 F
UTM: 2000KIP