Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 211588 DEA: 030F3104 EFIS: 0300000078
QA Service Level: 1
DIST-CO-RTE-PM: 03-ED-49-23.6/24.5
Work Description: REPLACE BRIDGE.
Location Description: EL DORADO COUNTY NEAR COLOMA FROM 0.1 MILE EAST OF MARSHALL ROAD TO 0.3 MILE EAST OF LOTUS ROAD
Contractor Name: M.C.M. CONSTRUCTION, INC.
Contractor Address: P.O. Box 620, North Highlands, CA 95660
Resident Engineer: Jeff Hamm Structure Rep.: Glen Wheeler
DIME Sample ID: 2017-04-10-4
TL Number from the TL Form: NA
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Retest
Type of Material: SMTL TM6 - Ductile Iron Cast Samples
Sample Taken Date: 04/10/2017
Date that the sample was received by the laboratory/organization performing the testing: 04/12/2017
The quantity of what the sample constitutes: 2
A brief description of the sample: Coupon Casting
From where was the sample collected: Distributor
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Goldens Foundary
Heat Number (s): 0517, 0397
Part Number (s): 68 31 216 246
Material Specification: A536
Grades: 65-45-12
Metal Foundry Manufacturer (Mill): Goldens Foundary
Prestressing Manufacturer: DSI
DIME Test ID: 2017-04-10-4-1
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Verified Date: 04/13/2017
Date Tested: 04/13/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
2
|
Sample | Heat Number | Diameter (in) | Area (sqin) | Stress at Offset (psi) | Tensile Strength (psi) | Elongation in 4 x d (%) | Tested By | | 0517 | 0.497 | 0.194 | 47580 | 78690 | 13.5 | Brian | | 0397 | 0.497 | 0.194 | 44376 | 69420 | 20.1 | Brian |
| |
UTM
|
67KIP
|
Temperature
|
72 F
|