Print Report | Back to Test Summary

Testing Report for 2017-03-24-4-1

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 080R1304
EFIS: 0812000027
Project ID: 211508
QA Service Level: 1
DIST-CO-RTE-PM: 08-SBD-62-16.8/25.2
Work Description: INSTALL TWO-WAY LEFT TURN LANES AND WIDEN SHOULDER
Location Description: SAN BERNARDINO COUNTY IN JOSHUA TREE AND NEAR TWENTY NINE PALMS AT VARIOUS LOCATIONS FROM 0.1 MILE EAST OF SHERWOOD ROAD TO 0.1 MILE EAST OF LEE DRIVE
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Khoi Vu
Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2017-03-24-4
TL Number from the TL Form: C953700
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (916) 227-7253
Type of Sample: Quality Assurance
Type of Material: SMTL TM5 - Welded Hoops
Sample Taken Date: 3/24/2017
Date that the sample was received by the laboratory/organization performing the testing: 3/29/2017
The quantity of what the sample constitutes: 4
A brief description of the sample: Flash Welded Rebar Hoops
From where was the sample collected: Fabricator
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Unknown

Material Information

Production or Authorization Testing: Authorization Testing
Service or Ultimate: Service
Rebar Heat Number(s): 4049973
Hoop Manufacturer Lot Number(s): 1
Material Standard Code: ASTM A706
Material Grade: 60
Rebar Size: 4
Diameter of Hoop: 2'-2"
Epoxy Coated: No
Epoxy Coating Color: NA
Rebar Manufacturer: TNT Rebar
Welding Company: TNT Rebar
Coating Standards: Uncoated
Weld Type: Flash Welded

Test Information

DIME Test ID: 2017-03-24-4-1
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Date Tested: 3/30/2017
Verified Date: 3/30/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test: Bar Broke; OK Necking
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Number of Samples: 1
Sample Mfg. Lot Number(s) Size Area (sqin) Peak Load (lbf) Peak Stress (psi) Comments Tested By
1 1 #4/13mm 0.2 19310 96550 Bar Broke Brian
UTM: 400KIP