Print Report | Back to Test Summary

Testing Report for 2017-03-22-1-2

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 020E0904
EFIS: 0200000016
Project ID: 210808
QA Service Level: 1
DIST-CO-RTE-PM: 02-SHA-5-R29.3/R31.1,R45.0/R45.8
Work Description: REPLACE BRIDGE, REALIGN ROADWAY AND SEISMIC RETROFIT
Location Description: IN SHASTA COUNTY ABT 8 MI N OF SHASTA LAKE CTY AND NEAR LAKEHEAD FRM TURNTABLE BAY O/C TO 0.1 MI N OF O'BRIEN SRRA & FRM 0.4 MI S TO 0.3 MI N OF DOG CREEK BRIDGE.
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Nathan Alexander
Structure Rep.: Christopher S 'Chris' Brace

Sample Information

DIME Sample ID: 2017-03-22-1
TL Number from the TL Form: C741361
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (916) 227-7253
Type of Sample: Quality Assurance
Type of Material: SMTL TM5 - Welded Hoops
Sample Taken Date: 3/22/2017
Date that the sample was received by the laboratory/organization performing the testing: 3/23/2017
The quantity of what the sample constitutes: 4
A brief description of the sample: Flash Welded Rebar Hoops
From where was the sample collected: Fabricator
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Harris Rebar

Material Information

Production or Authorization Testing: Production Testing
Service or Ultimate: Ultimate
Rebar Heat Number(s): SE16104901
Hoop Manufacturer Lot Number(s): H34
Material Standard Code: ASTM A706
Material Grade: 60
Rebar Size: 8
Diameter of Hoop: 6'-8"
Epoxy Coated: No
Epoxy Coating Color: NA
Rebar Manufacturer: Nucor
Welding Company: Harris Rebar
Coating Standards: Uncoated
Weld Type: Flash Welded

Test Information

DIME Test ID: 2017-03-22-1-2
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Date Tested: 3/24/2017
Verified Date: 3/24/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test: Bar Broke; OK Necking
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Number of Samples: 1
Sample Mfg. Lot Number(s) Size Area (sqin) Peak Load (lbf) Peak Stress (psi) Comments Tested By
2 H34 #8/25mm 0.79 73530 93080 Bar Broke Fred
UTM: 400KIP
Temperature: 72 F