Print Report | Back to Sample Detail

Sample Record for 2017-01-31-8

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 209950 DEA: 080N56U4 EFIS: 0813000176 QA Service Level: 1
DIST-CO-RTE-PM: 08-SBD-40-R94.7/R99.7
Work Description: BRIDGE REPLACEMENTS.
Location Description: SAN BERNARDINO COUNTY NEAR ESSEX AT HALLER WASH BRIDGE AT ROJO WASH BRIDGE AND AT CLIPPER VALLEY WASH BRIDGE
Contractor Name: OHL USA, INC.
Contractor Address: 1920 MAIN STREET STE 310, Irvine, CA 92614
Resident Engineer: Darcy Davis Structure Rep.: Leonard Romero

Sample Information

DIME Sample ID: 2017-01-31-8
TL Number from the TL Form: 178314
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 01/31/2017
Date that the sample was received by the laboratory/organization performing the testing: 02/06/2017
The quantity of what the sample constitutes: 2
A brief description of the sample: 6X12
From where was the sample collected: Job Site
Laboratory sample identification: 907-14
Structure unique identifier: BRIDGE DECK
Structure name: FIRST SAMPLE OF FRAME ONE
The fabricator/manufacturer/facility name: ROBERTSONS

Material Information

The concrete mix design number: RRM16074
The truck number from where the sample was collected: Unknown
The batch plant ticket number from where the sample was collected: NP
Concrete batch plant: Unknown
The fabricator/manufacturer designation for the sample: Unknown
A detailed description of where the material sample was collected: LOAD 8
Where the material sample would have been placed if not sampled: Unknown
From Lot No.: Unknown
Bag Lot No.: Unknown

Test Results

Test 1 of 1

DIME Test ID: 2017-01-31-8-1
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 02/28/2017
Date Tested: 02/28/2017
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With no density determined
Capped in accordance with? ASTM C617/CTM521
Average diameter of cylinder 1 6.01 in
Average diameter of cylinder 2 5.99 in
Cross sectional area of cylinder 1 28.37 in^2
Cross sectional area of cylinder 2 28.18 in^2
Compressive strength (to nearest 10 psi) 5130 psi
Maximum load on cylinder 1 154680 lb
Maximum load on cylinder 2 135570 lb
Compressive strength of cylinder 1 5452.2 psi
Type of fracture pattern of cylinder 1 2
Compressive strength of cylinder 2 4810.9 psi
Type of fracture pattern of cylinder 2 1
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 no data
Age of specimen 28 days
Age of specimen in hours no data