Testing Report for 2017-01-31-5-2

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 080M2804
EFIS: 0800000472
Project ID: 210696
QA Service Level: 1
DIST-CO-RTE-PM: 08-SBD-15-171.8/173.8
Work Description: BRIDGE REPLACEMENT AND WIDEN, CONC AND HMA PVMT, COLD PLANE AC PVMT.
Location Description: In SBD County
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: John Santos
Structure Rep.: Faisal Zahlout

Sample Information

DIME Sample ID: 2017-01-31-5
TL Number from the TL Form: 014
Sample Submitted By Organization: CT - Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 1/31/2017
Date that the sample was received by the laboratory/organization performing the testing: 2/6/2017
The quantity of what the sample constitutes: 8
A brief description of the sample: 6x12
From where was the sample collected: Job Site
Laboratory sample identification: 942-14
Structure unique identifier: MT PASS 03M S OF CENDA DITCH BR TO WHEATON WASH BR
Structure name: CENDA BR ABUTMENT 1 APPROACH SLAB
The fabricator/manufacturer/facility name: CALPORTLAND

Material Information

The concrete mix design number: P40AF033
The truck number from where the sample was collected: 8048
The batch plant ticket number from where the sample was collected: S496513
Concrete batch plant: Unknown
The fabricator/manufacturer designation for the sample: Unknown
A detailed description of where the material sample was collected: TRUCK
Where the material sample would have been placed if not sampled: Unknown
From Lot No.: Unknown
Bag Lot No.: Unknown

Test Information

DIME Test ID: 2017-01-31-5-2
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Date Tested: 2/21/2017
Verified Date: 2/21/2017
Submitted By Organization: CT - Southern Regional Laboratory
Organization Address: 13970 Victoria St,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 213-792-4794
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 5.97 in
Average diameter of cylinder 2: 5.98 in
Cross sectional area of cylinder 1: 27.99 in^2
Cross sectional area of cylinder 2: 28.09 in^2
Compressive strength (to nearest 10 psi): 4430 psi
Maximum load on cylinder 1: 122240 lb
Maximum load on cylinder 2: 126160 lb
Compressive strength of cylinder 1: 4367.3 psi
Type of fracture pattern of cylinder 1: 2
Compressive strength of cylinder 2: 4491.3 psi
Type of fracture pattern of cylinder 2: 3
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: no data
Age of specimen: 21 days
Age of specimen in hours: no data