Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 210097 DEA: 100L9704 EFIS: 1012000053
QA Service Level: 1
DIST-CO-RTE-PM: 10-TUO-120-R19.5/R20.0
Work Description: REPLACE DECK AND RETROFIT BRIDGE.
Location Description: IN TUOLUMNE COUNTY ON STATE ROUTE 120 FROM 7.6 MILES EAST OF YOSEMITEJUNCTION TO 4.8 MILES WEST OF THE TOWN OF MOCCASIN AT TUOLUMNE RIVER/DON PEDRO RESERVOIR (JAMES E.
Contractor Name: Golden State Bridge
Contractor Address: 3701 Mallard Drive, Benicia, CA 94510
Resident Engineer: Corey Casey Structure Rep.: Ehab Wahed
DIME Sample ID: 2017-02-06-2
TL Number from the TL Form: Unknown
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Verification
Type of Material: SMTL TM6 - Steel Check Sample Plate
Sample Taken Date: 02/06/2017
Date that the sample was received by the laboratory/organization performing the testing: 02/07/2017
The quantity of what the sample constitutes: 3
A brief description of the sample: A514 Steel Check Sample
From where was the sample collected: Job Site
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Kloecenter Metals
Heat Number(s): 7797637 7797016
Material Specification: A572
Grade: HPS 100W
Thickness: 1" .375"
Shape: Rectangle
Metal Foundry Manufacturer (Mill): Kloecenter Metals
Plate Dimension: 1"
DIME Test ID: 2017-02-06-2-1
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Verified Date: 02/09/2017
Date Tested: 02/08/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
2
|
Sample | Heat Number | Diameter (in) | Area (sqin) | Stress at Offset (psi) | Tensile Strength (psi) | Elongation in 4 x d (%) | Tested By | | 7797637 | 0.496 | 0.1932 | 113967 | 120570 | 19.6 | Brian | | 7797637 | 0.498 | 0.1948 | 114012 | 120710 | 20.3 | Brian |
| |
UTM
|
67KIP
|
Temperature
|
72 F
|
DIME Test ID: 2017-02-06-2-2
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Flat Sample)
Verified Date: 02/09/2017
Date Tested: 02/08/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Sample | Heat Number | Width (in) | Area (sqin) | Stress at Offset (psi) | Tensile Strength (psi) | Total Elongation (%) | Tested By | | 7797016 | 0.506 | 0.1943 | 108769 | 117643 | 16.4 | Brian |
| |
UTM
|
67KIP
|
Temperature
|
72 F
|
DIME Test ID: 2017-02-06-2-3
Test Method: SMTL CHEM-16: Steel Chemistry Analysis
Verified Date: 02/09/2017
Date Tested: 02/09/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified: