Print Report | Back to Test Summary

Testing Report for 2017-02-06-2-1

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 100L9704
EFIS: 1012000053
Project ID: 210097
QA Service Level: 1
DIST-CO-RTE-PM: 10-TUO-120-R19.5/R20.0
Work Description: REPLACE DECK AND RETROFIT BRIDGE.
Location Description: IN TUOLUMNE COUNTY ON STATE ROUTE 120 FROM 7.6 MILES EAST OF YOSEMITEJUNCTION TO 4.8 MILES WEST OF THE TOWN OF MOCCASIN AT TUOLUMNE RIVER/DON PEDRO RESERVOIR (JAMES E.
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Corey Casey
Structure Rep.: Ehab Wahed

Sample Information

DIME Sample ID: 2017-02-06-2
TL Number from the TL Form: Unknown
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (916) 227-7253
Type of Sample: Verification
Type of Material: SMTL TM6 - Steel Check Sample Plate
Sample Taken Date: 2/6/2017
Date that the sample was received by the laboratory/organization performing the testing: 2/7/2017
The quantity of what the sample constitutes: 3
A brief description of the sample: A514 Steel Check Sample
From where was the sample collected: Job Site
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Kloecenter Metals

Material Information

Heat Number(s): 7797637 7797016
Material Specification: A572
Grade: HPS 100W
Thickness: 1" .375"
Shape: Rectangle
Metal Foundry Manufacturer (Mill): Kloecenter Metals
Plate Dimension: 1"

Test Information

DIME Test ID: 2017-02-06-2-1
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Date Tested: 2/8/2017
Verified Date: 2/9/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Number of Samples: 2
Sample Heat Number Diameter (in) Area (sqin) Stress at Offset (psi) Tensile Strength (psi) Elongation in 4 x d (%) Tested By
7797637 0.496 0.1932 113967 120570 19.6 Brian
7797637 0.498 0.1948 114012 120710 20.3 Brian
UTM: 67KIP
Temperature: 72 F