Print Report | Back to Test Summary

Testing Report for 2016-11-30-6-3

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 080K8414
EFIS: 0814000073
Project ID: 211392
QA Service Level: 1
DIST-CO-RTE-PM: 08-SBD-L5726-L5726
Work Description: CONSTRUCT OFFICE BUILDING
Location Description: SAN BERNARDINO COUNTY AT THE CALTRANS MAINTENANCE STATION 175 WEST CLUSTER STREET SAN BERNARDINO, CALIFORNIA 92402
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Al-Hakem Alina
Structure Rep.: Al-Hakem Alina

Sample Information

DIME Sample ID: 2016-11-30-6
TL Number from the TL Form: 1130
Sample Submitted By Organization: CT - Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 11/30/2016
Date that the sample was received by the laboratory/organization performing the testing: 12/2/2016
The quantity of what the sample constitutes: 8
A brief description of the sample: 6x12 concrete cylinders
From where was the sample collected: Job Site
Laboratory sample identification: 954-1130
Structure unique identifier: Unknown
Structure name: OFFICE BUILDING
The fabricator/manufacturer/facility name: ROBERTSONS REDLAND

Material Information

The concrete mix design number: SC590B38
The truck number from where the sample was collected: NOT PROVIDED
The batch plant ticket number from where the sample was collected: NOT PROVIDED
Concrete batch plant: Unknown
The fabricator/manufacturer designation for the sample: Unknown
A detailed description of where the material sample was collected: CHUE
Where the material sample would have been placed if not sampled: SLAB FOR OFFICE BUILDING AT CLUSTER MAINTENANCE IN SBD
From Lot No.: Unknown
Bag Lot No.: Unknown

Test Information

DIME Test ID: 2016-11-30-6-3
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Date Tested: 12/21/2016
Verified Date: 1/24/2017
Submitted By Organization: CT - Southern Regional Laboratory
Organization Address: 13970 Victoria St,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 213-792-4794
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 6.00 in
Average diameter of cylinder 2: 6.02 in
Cross sectional area of cylinder 1: 28.27 in^2
Cross sectional area of cylinder 2: 28.46 in^2
Compressive strength (to nearest 10 psi): 4530 psi
Maximum load on cylinder 1: 127470 lb
Maximum load on cylinder 2: 129320 lb
Compressive strength of cylinder 1: 4509.0 psi
Type of fracture pattern of cylinder 1: 3
Compressive strength of cylinder 2: 4543.9 psi
Type of fracture pattern of cylinder 2: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: no data
Age of specimen: 21 days
Age of specimen in hours: no data