Print Report | Back to Sample Detail

Sample Record for 2017-01-06-1

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 209384 DEA: 04264094 EFIS: 0400000735 COOP: 042531 QA Service Level: 1
DIST-CO-RTE-PM: 04-,SON--
Work Description:
Location Description:
Contractor Name: GHILOTTI BROS / RM HARRIS JV
Contractor Address: 525 Jacoby Street, San Rafael, CA 94901
Resident Engineer: Richard Duncan Structure Rep.: Brian Beaudoin

Sample Information

DIME Sample ID: 2017-01-06-1
TL Number from the TL Form: C719136
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM7 - Epoxy Coated Rebar
Sample Taken Date: 01/06/2017
Date that the sample was received by the laboratory/organization performing the testing: 01/10/2017
The quantity of what the sample constitutes: 2
A brief description of the sample: Epoxy Coated Rebar
From where was the sample collected: Source
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Western Coating

Material Information

Rebar Heat Number(s): PL16108427
Rebar Epoxy Batch Number(s): 3395646
Rebar Coating Specification: ASTM A775
Rebar Size (#): 4/13
Rebar Coating Color: Green
Rebar Manufacturer: Nucor
Rebar Coater: Western Coating
Rebar Powder Manufacturer: Axalta
Release Number: Unknown
Quality Assurance Code: Unknown

Test Results

Test 1 of 2

DIME Test ID: 2017-01-06-1-1
Test Method: ASTM A775-07b-re14: Standard Specification for Epoxy-Coated Steel Reinforcing Bars (Epoxy Coating)
Verified Date: 01/12/2017
Date Tested: 01/11/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
First Bar Mean 7.35 mils
Second Bar Mean 8.91 mils
Lower spec. limit LSL 7 mils
Upper spec. limit USL 12 mils
Bar # for First Bar no data
Bar # for Second Bar no data
Total mean value 8.13 mils
Total number of values less than LSL no data
Total number of values greater than USL no data

Test 2 of 2

DIME Test ID: 2017-01-06-1-2
Test Method: ASTM A775-07b-re14: Standard Specification for Epoxy-Coated Steel Reinforcing Bars (Holiday)
Verified Date: 01/12/2017
Date Tested: 01/11/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Total Number of Holiday 0
Total Length 5 ft
Holidays Per Linear Foot of Bar 0 holiday pe
Holiday Test Pass/Fail Pass
Bend Test Pass/Fail Pass